7.
Type firmwareDownload -s to download the firmware to one of the CP blades. Enter all requested
information (use default values):
swDir:admin> firmwaredownload -s
Server Name or IP Address: 192.168.100.1
User Name: user
File Name: /software/v6.0.0/release.plist
Password: ********
Do Auto-Commit after Reboot [Y]:
Reboot system after download [N]:
Firmwaredownload has started.
2007/07/03-14:59:21, [SULB-1001], 923,,
WARNING, DC Director, Firmwaredownload command has started.
Start to install packages......
dir
ldconfig
glibc
bash
readline
terminfo
termcap
setup
<output truncated>
tz
mtracer-tool
lkcd
sysstat
Removing unneeded files, please wait ...
Finished removing unneeded files.
All packages have been downloaded successfully.
Firmwaredownload has completed successfully.
2007/07/03-15:05:56, [SULB-1002], 924,, INFO, DC Director,
Firmwaredownload command has completed successfully.
8.
Type firmwareDownloadStatus to verify that the firmware has been updated.
9.
Type haEnable to re-enable HA on the active CP blade.
10.
Type reboot.
11.
Verify that the reboot is complete and the CP blades have achieved failover redundancy:
a.
Wait until the status LEDs on both CP blades are not lit.
b.
Type haShow and verify that the command output includes HA Enabled Heartbeat Up. If not,
re-enter the command until you have verified that redundancy is achieved.
12.
Type firmwareShow to verify that the firmware version has been updated.
13.
Pack the faulty CP blade in the packaging provided with the new CP blade, and contact HP for
the procedure for returning the faulty blade.
14.
Replace the chassis door. See
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
"Installing the chassis
HP StorageWorks DC and DC04 SAN Backbone Director Switches
door" on page 74.