Monitoring Core Switch Blade (Cr8) Status; Cp Blade Led Descriptions - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Table 10
describes the CP blade LED patterns and the recommended actions for those patterns.
Table 10 CP blade LED descriptions
LED pur-
Color
pose
Power
Steady green
No light (LED is off)
Status
No light (LED is off)
Steady amber
Slow-flashing amber (on
2 seconds; then off 2
seconds)
Fast-flashing amber (on
1/2 second; then off
1/2 second)
Ethernet
No light (LED is off)
Link
Status
Flickering green/amber
Ethernet
No light (LED is off)
Link
Speed
Steady green
Active
Steady blue
CP
No light (LED is off)

Monitoring core switch blade (CR8) status

To determine the status of a CR blade:
1.
Check the LED indicators on the core switch blade (see
temporarily change during POST and other diagnostic tests; for information about how to interpret
the LED patterns, see
2.
Check core switch blade status by typing slotShow and haShow.
66
Monitoring DC SAN Director system components
Status
CP blade has valid power.
CP blade does not have incoming
power.
CP blade is either healthy or does
not have power.
CP blade is faulty or the switch is
still booting.
CP blade is not seated correctly
or is faulty.
Environmental range exceeded.
Either an Ethernet link is not detec-
ted, or it does not have incoming
power.
Ethernet link is healthy and traffic
is flowing through port.
Ethernet link speed is 10 Mb/s
or CP blade does not have incom-
ing power.
Ethernet link speed is 100/1000
Mb/s.
Active CP blade.
Standby CP blade.
Table
10.
Recommended action
No action required
Ensure blade is firmly seated and
has power.
Verify that the power LED is on.
Ensure blade is firmly seated and
switch has completed booting. If LED
remains yellow, contact HP.
Pull blade out and reseat it. If LED
continues to flash, replace blade.
Check for out-of-bounds environment-
al condition and correct it.
Ensure the blade has power, Ethernet
cable is firmly seated, and connec-
ted device is functioning.
No action required
Ensure CP has power.NOTE: To force
a persistent Ethernet link speed, type
the ifModeSet command.
No action required
No action required
No action required
Figure
22). The LED patterns may