Installing A Core Switch Blade (Cr8); Core Switch Blade (Cr8) - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2.
Power off the blade by sliding the slider switch in the top ejector down to the off position (see
Figure
31).
3.
Disconnect cables from the faulty core switch blade.
4.
Unscrew the thumb screw from both ejectors using the Phillips screwdriver.
5.
Open both ejector handles simultaneously to approximately 45 degrees and pull the core switch
blade out of the chassis (see
Figure 31 Core switch blade (CR8)

Installing a core switch blade (CR8)

To install a CR blade (slot 5 or 6):
CAUTION:
Wear a grounded ESD strap when handling a CR8 blade. Use the grounding connections above the
power connectors on the chassis.
1.
Open the ejector handles to approximately 45 degrees, and then orient the CP blade so that the
handles are toward you and the flat metal side is on your left.
2.
Align the flat metal side of the core switch blade inside the lower and upper blade guides in the
slot, and then slide the core switch blade into the slot until it is firmly seated (see
3.
Tighten the thumb screw inside each handle using the Phillips screwdriver.
Figure
31).
HP StorageWorks DC and DC04 SAN Backbone Director Switches
26386a
Figure
31).
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents