Verifying That The Configuration Of The Fabric Is Correct - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Verifying that the configuration of the fabric is correct

Copying the command outputs from this section into a file is recommended.
To verify correct configuration of the fabric:
1.
Create an "after" SAN profile by entering the following commands and copying the output to a
text file named SANafter.txt:
• nsShow
• nsAllShow
• switchShow
• fabricShow
rsl8-st03-dcx-1:admin> nsshow
Type Pid
N
<output truncated>
rsl8-st03-dcx-1:admin> nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
rsl8-st03-dcx-1:admin> switchshow
switchName: rsl8-st03-dcx-01
<output truncated>
rsl8-st03-dcx-1:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
rsl8-st03-dcx-1:admin>
2.
Determine any differences between the information in the SANafter.txt file and the information
in the SANbefor.txt file created earlier. In particular, look for differences in the following:
• Device types
• Number of devices
• ISL and port states
• Number of switches in the fabric
COS
PortName NodeName TTL(sec)
020f00;
3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
HP StorageWorks DC and DC04 SAN Backbone Director Switches