HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual page 107

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3.
Verify that the DC SAN Director is functioning correctly by typing switchShow or switchStatusShow.
This switchShow command displays DC SAN Director and port status information.
rsl8-st03-dcx-1:admin> switchshow
switchName:
switchType:
switchState:
switchMode:
switchRole:
switchDomain:
switchId:
switchWwn:
zoning:
switchBeacon:
blade3 Beacon:
blade5 Beacon:
blade8 Beacon:
blade10Beacon:
Index
Slot
PortAddressMediaSpeedStateProto
===========================================================
32
3
00b2000idN4OnlineL-Port 5 public
33
3
10b2100__N8No_Module
34
3
20b2200__N8No_Module
35
3
30b2300__N8No_Module
36
3
40b2400idN4OnlineF-Port
10:00:00:00:c9:51:00:2d
37
3
50b2500__N8No_Module
rsl8-st03-dcx-1:admin>
4.
Verify that all the IP address information is correct by typing ipAddrShow and checking the results
against the IP information recorded in the config-miscinfo.txt file.
rsl8-st03-dcx-1:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>
rsl8-st03-dcx-1
62.1
Online
Native
Subordinate
11
fffc0b
10:00:00:05:1e:39:59:67
OFF
OFF
OFF
OFF
OFF
OFF
HP StorageWorks DC and DC04 SAN Backbone Director Switches
107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents