Disconnecting From The Network And The Fabric - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

e.
Type supportShow, then copy the command output into a text file named spptshow.txt.
NOTE:
The supportShow command has a very long output and time for completion. It may
last 20 minutes or longer depending on the size of the SAN.
This file provides a backup of all the information that might be required by Technical Support.
The information can be used after the DC04 SAN Director is restored to the fabric, to verify
that no unintentional changes have occurred to the fabric.
rsl8-st03-dcx-1:admin> supportshow
version: 6.0.0
<output truncated>
rsl8-st03-dcx-1:admin>
f.
Record the cable connections between the DC04 SAN Director and the target device and
ports (see

Disconnecting from the network and the fabric

To disconnect from the network and fabric:
1.
Shut down the DC04 SAN Director using the sysShutdown command.
rsl8-st03-dcx-1:admin> sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 1
Shutting down the blade....
Stopping blade 4
Shutting down the blade....
Stopping blade 10
Shutting down the blade....
Broadcast message from root (pts/1) Tue Jul 18 14:23:06 2006...
The system is going down for system halt NOW !!
CAUTION:
Turn off the power switches and disconnect the power cords.
2.
Power off the chassis by setting the AC power switches to "0". (The power supply Status LED
should turn off.)
3.
Remove the power cords from the power supplies and the power outlets.
4.
Label the cables connected to all blades and record the connections in
5.
Remove the chassis door.
6.
Disconnect the cables from the port blades and set them aside. The SFP or XFP transceivers can
be left in the port blades or removed.
198
Replacing DC04 SAN Director field-replaceable units (FRUs)
Table
40).
Table
40.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents