Blower Assembly; Blower Assembly Led Descriptions - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2.
Check the blower assembly status using the fanShow command.
The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the
assembly is also provided. If a blower assembly is absent or faulty, contact HP.
1. Power LED
Table 34 Blower assembly LED descriptions
LED
Color
pur-
pose
Power
No light (LED is off)
Steady green
Fault
No light (LED is off)
Steady amber
Slow-flashing amber (on
2 sec, then off 2 sec)
166
Monitoring DC04 SAN Director system components
Figure 61 Blower assembly
2. Fault LED
Status
Blower assembly does not
have incoming power.
Blower assembly has incoming
power.
Blower assembly is either
healthy or does not have in-
coming power.
Blower assembly has a failure
(full or partial).
Blower assembly is not seated
correctly or is faulty.
Recommended action
Ensure that the blower assembly is
firmly seated and has power.
No action required
Ensure that the blower assembly
has incoming power.
Replace blower assembly.
Pull unit out and reseat. If LED con-
tinues to flash, replace unit.