Installing The Dc04 San Director In The Cabinet - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

NOTE:
The screws, clip nuts, and retainer nuts used to secure the DC04 SAN Director to the cabinet are
provided in the DC04 SAN Director hardware accessory kit.
To install the DC04 SAN Director in the cabinet:
1.
Remove the chassis door from the DC04 SAN Director. See
2.
Use a lift to raise the chassis to the correct level. Position the lift as close as possible to the rack.
3.
If applicable, lock the wheels on the lift.
4.
Carefully lift the DC04 SAN Director and slide it into the cabinet.
5.
Secure the DC04 SAN Director to the cabinet using six 10-32 screws with washers. See
44.
• For rails with round holes—Use the clip nuts (F in
the 10-32 screws.
• For rails with square holes—Use the retainer nuts (G in
securing the 10-32 screws.
Tighten the screws according to the specifications listed in
Figure 44 Installing the DC04 SAN Director in the cabinet
6.
Reinstall the chassis door. See
HP StorageWorks DC and DC04 SAN Backbone Director Switches
Figure
Installing the chassis
door, page 170.
Removing the chassis
door, page 169.
39, page 130) on the rails for securing
Figure
39, page 130) on the rails for
Table
28, page 130.
Figure
135