Table 1 1
describes the power supply LED patterns and the recommended actions for those patterns.
Table 1 1
Power supply LED descriptions
LED purpose
Power
Blower assembly
To determine the status of a blower assembly:
1.
Check the LED indicators on the blower assembly
change during POST and other diagnostic tests; for information about how to interpret the LED
patterns, see
2.
Check the blower assembly status using the fanShow command.
The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the
assembly is also provided. If a blower assembly is absent or faulty, contact HP.
Figure 24
displays the blower assembly.
Figure 24
Blower assembly
1
Power LED
Color
Status
No light
Power supply does not have
(LED is off)
incoming power and is not
providing power to the DC
Director.
Steady green
Power supply has incoming
power and is providing power
to the DC Director.
Flashing green
Power supply is about to fail.
Table
12.
1
2
Recommended action
Ensure power supply is firmly
seated, DC Director has
incoming power, both power
cables are connected, and AC
power switches are on.
No action required.
Replace power supply.
(Figure
24). The LED patterns may temporarily
2
Fault LED
DC SAN Backbone Director hardware reference guide
59