Open both ejector handles simultaneously to approximately 45 degrees and pull the CP blade
out of the chassis (see
Figure 30 Control processor blade (CP8)

Installing a control processor blade (CP8)

To install a CP blade (slot 6 or 7):
CAUTION:
Wear a grounded ESD strap when handling a CP8 blade. Use the grounding connections above the
power connectors on the chassis.
1.
Open the ejector handles to approximately 45 degrees. Orient the CP blade so that the handles
are toward you and the flat metal side is on your left.
2.
Align the flat metal side of the CP blade inside the lower and upper blade guides in the slot.
Slide the CP blade into the slot until it is firmly seated, see
3.
Tighten the thumb screw inside each handle using the Phillips screwdriver.
4.
Turn the CP blade on by sliding the ON/OFF switch in the top handle up, to cover the thumb
screw.
5.
Verify that the power LED is green. If it is not, ensure that the CP blade has power and is firmly
seated and that the ejectors are in the locked position.
6.
Connect the cables to the new CP blade.
Figure
30).
HP StorageWorks DC and DC04 SAN Backbone Director Switches
26385a
Figure
30).