Installing A Core Switch Blade; Core Switch Blade (Cr4S-8) - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Figure 68 Core switch blade (CR4S-8)

Installing a core switch blade

To install a CR blade (slot 3 or 6):
CAUTION:
Wear a grounded ESD strap when handling a CR4S-8 blade. Use the grounding connections above
the power connectors on the chassis.
1.
Open the ejector handles to approximately 45 degrees, and then orient the CR blade so that the
handles are toward you and the flat metal side is on the bottom.
2.
Align the flat metal side of the core switch blade inside the left and right blade guides in the slot,
and then slide the core switch blade into the slot until it is firmly seated (see
3.
Tighten the thumb screw inside each handle using the Phillips screwdriver.
4.
Turn the core switch blade on by sliding the ON/OFF switch in the left handle to the left to cover
the thumb screw.
5.
Verify that the power LED is green (this may require a few seconds). If not, ensure that the core
switch blade has power and is firmly seated and that the ejectors are in the locked position.
6.
Connect to the new core switch blade.
7.
Pack the faulty core switch blade in the packaging provided with the new core switch blade,
and contact the DC04 SAN Director supplier for the procedure for returning the faulty blade.
HP StorageWorks DC and DC04 SAN Backbone Director Switches