4.
Use a pallet jack or other assisted lift to transport the new chassis to the installation area. Doorways
must be wider than 91 cm (36 in) to accommodate the chassis on the pallet.
5.
Use a lift to raise the chassis to the correct level. If installing the chassis in a cabinet, follow the
instructions provided by the rack kit manufacturer.

Installing components into the new chassis

Install the field replaceable units (FRUs) in the chassis.
CAUTION:
Wear a grounded ESD strap when handling DC04 SAN Director components and port blades. The
chassis provides a grounding connection above the power connectors. Also, store ESD-sensitive
components in antistatic packaging.
1.
Replace the WWN bezel (logo plate) and WWN cards (see
"Installing the WWN bezel (logo plate) and WWN
2.
Replace the blower assemblies (see
3.
Replace the power supplies or filler panels (see
4.
Replace the control processor blades (CP8) (see
"Installing a control processor blade
5.
Replace the core switch blades (CR8) (see
6.
Replace the port blades or filler panels (see
7.
Replace the cable management fingers (see
"Installing a cable management finger
8.
Connect the power cords to the power supplies and the power outlets.
9.
Replace the chassis door (see
10.
Power-on the DC04 SAN Director.
11.
The DC04 SAN Director performs a power-on self-test (POST). The POST takes a minimum of
three minutes and is complete when LED activity returns to standard state.
12.
Verify that the DC04 SAN Director is powered on and POST is complete (all power LED indicators
on the port, control processor, and core switch blades should be a steady green).
13.
Verify that all components are functioning correctly by checking their LEDs. If the LEDs do not
indicate correct operation, try reinstalling the corresponding component.

Configuring the new chassis serial number

To configure a new chassis serial number:
200
Replacing DC04 SAN Director field-replaceable units (FRUs)
card" on page 191).
"Installing a blower
"Installing a power
(CP8)" on page 179).
"Installing a core switch
"Installing a
assembly" on page 171).
Installing the chassis
door).
assembly" on page 186).
supply" on page 184).
blade" on page 183).
blade" on page 173).