3.
Check the error message indicating the status of the WWN unit (see
chassisShow command to determine the status of the WWN unit.
Table 18 WWN card related system log messages
Type of message
WWN unit removal was detected
WWN unit insertion was detected
WWN unit fails to power on
WWN unit is being faulted
Removing the WWN bezel (logo plate) and WWN card
To remove the WWN bezel and WWN card:
CAUTION:
Wear a grounded ESD strap when handling the WWN card. Use the grounding connections above
the power connectors on the chassis.
1.
Open a Telnet session to the DC SAN Director and log in to the active CP as admin. The default
password is "password".
2.
Verify that you are logged into the active CP. Run the haShow command to determine the active
CP.
3.
Type fruReplace wwn from the active CP blade and wait for the phrase "Do you wish to
continue [y/n]?" to display; then type y.
System message (errshow or errdump)
<timestamp>, [EM-1050], <sequence-number>,,
INFO, <system-name>, FRU WWN # removal detected.
<timestamp>, [EM-1049], <sequence-number>,,
INFO, <system-name>, FRU WWN # insertion detec-
ted.
<timestamp>, [EM-1004], <sequence-number>,,
CRITICAL, <system-name>, WWN # failed to power
on
<timestamp>, [EM-1034], <sequence-number>,, ER-
ROR, <system-name>, WWN # set to faulty,
rc=<return code>
HP StorageWorks DC and DC04 SAN Backbone Director Switches
Table
18). Type the
93