Installing a New GbE2 Interconnect Switch for a New Deployment

To install a new GbE2 Interconnect Switch for a new deployment:
1. Insert the interconnect modules into the bottom-left and bottom-right module bays on the
rear side of the server blade enclosure.
IMPORTANT: Be sure that the interconnect modules are fully seated. The latch/handle will drop
into place when the module is firmly seated.
Figure 2-1: Installing the QuadT2 or QuadSX Interconnect Modules
2. Slide one GbE2 Interconnect Switch into the right interconnect bay in the front side of
the server blade enclosure (1). The GbE2 Interconnect Switch in the right interconnect
bay is referred to as Switch B.
3. Lock the ejector lever (2).
Figure 2-2: Installing the GbE2 Interconnect Switches
4. Repeat steps 2 and 3 to insert the second GbE2 Interconnect Switch in the left
interconnect bay. The GbE2 Interconnect Switch in the left interconnect bay is referred to
as Switch A.