Configuring PoE Settings (7024P/7048P Only)

Beginning in Privileged EXEC mode, use the following commands to
configure PoE information.
Command
configure
power inline usage-
threshold
threshold
power inline priority
enable
power inline
management {static |
dynamic}
power inline detection
{dot3af | dot3af+legacy
| legacy-only}
interface
interface
power inline {auto |
never}
power inline priority
{critical | high |
medium | low}
Purpose
Enter Global Configuration mode.
Specify the maximum usage for PoE power on the system.
threshold
The
variable (range: 12–99%) is a percentage of
total system power.
Enable the port priority feature on the switch.
Set the power-management mode for the switch.
Set the power-management mode for the switch.
• 802.3af-only—IEEE 802.3af detection scheme is used.
• 802.3af+legacy—IEEE 802.3af 4point detection scheme
is used and when it fails to detect a connected PD, legacy
capacitive detection is used.
• legacy-only—only legacy capacitive detection scheme is
used.
Enter interface configuration mode for the specified port.
interface
The
variable includes the interface type and
number, for example gigabitethernet 1/0/3.
Set the PoE device discovery admin mode.
• auto — Enables the device discovery protocol and, if
found, supplies power to the device.
• never — Disables the device discovery protocol and stops
supplying power to the device.
Configures the port priority level for the delivery of power
to an attached device.