System Cooling Fans Do Not Rotate Properly
If the system cooling fans are not operating properly, it is an indication of possible system
component failure.
Check the following:
•
Is the power-on light lit? If not, see
•
Are any other control panel LEDs lit?
•
Have your fans speeded up in response to an overheating situation?
•
Have your fans speeded up in response to a fan that has failed?
•
Are the fan power connectors properly connected to the server board?
•
Are the power supply cables properly connected to the server board?
•
Are there any shorted wires caused by pinched-cables or have power connector
plugs been forced into power connector sockets the wrong way?
Cannot Connect to a Server
•
Make sure the network cable is securely attached to the correct connector at the
system back panel.
•
Try a different network cable.
•
Make sure you are using the correct and the current drivers. See
Information and Software"
•
Make sure the driver is loaded and the protocols are bound.
•
Make sure the hub port is configured for the same duplex mode as the network
controller.
•
Make sure the correct networking software is installed.
•
If you are directly connecting two servers (without a hub), you will need a crossover
cable.
•
Check the network controller LEDs next to the NIC connectors.
®