Characters Are Distorted Or Incorrect; System Cooling Fans Do Not Rotate Properly - Intel SR1520ML - Server System - 0 MB RAM User Manual

Server system
Table of Contents

Advertisement

Remove the memory DIMMs and re-seat them.
Make sure the processor(s) comply with the system requirements.
Make sure the processor(s) have been populated according to the system
requirements.
Remove the processor(s) and re-seat them.
If you are using an add-in video controller board, do the following:
1. Verify that the video works using the onboard video controller.
2. Verify that the video controller board is fully seated in the server board connector.
3. Reboot the system for changes to take effect.
4. If there are still no characters on the screen after you reboot the system and POST
emits a beep code, write down the beep code you hear. This information is useful
for your service representative.
5. If you do not receive a beep code and characters do not appear, the video display
monitor or video controller may have failed. Contact your service representative or
authorized dealer for help.

Characters Are Distorted or Incorrect

Check the following:
Are the brightness and contrast controls properly adjusted on the video monitor? See
the manufacturer's documentation.
Are the video monitor's signal and power cables properly installed?
Does this video monitor work correctly if plugged into a different system?

System Cooling Fans Do Not Rotate Properly

If the system cooling fans are not operating properly, it is an indication of possible system
component failure.
Check the following:
Is the power-on light lit? If not, see
Are any other control panel LEDs lit?
Have any of the fan motors stopped? Use the server management subsystem to
check the fan status.
Have your fans speeded up in response to an overheating situation?
Have your fans speeded up in response to a fan that has failed?
Are the fan power connectors properly connected to the server board?
Is the cable from the control panel board connected to the both the control panel
board and to the server board?
®
Intel
Server System SR1520ML User's Guide
"Power Light Does Not Light" on page
92.
93

Advertisement

Table of Contents
loading

Table of Contents