Intel SR1680MV - Server System - 0 MB RAM Service Manual page 27

A guide for technically qualified assemblers of intel identified subassemblies/products
Table of Contents

Advertisement

Feature
System Health LED
HDD Activity LED
NIC 1&2 LED
UID LED
NIC 0&1 Activity LED
NIC 0&1 Link LED
UID LED
AC Power LED
®
Intel
Server System SR1680MV Service Guide
Table 2. LED Information
Color
Red
Blinking: System has non-critical errors. After error
condition is cleared, LED is off.
On: System has critical errors. LED needs to remain
active until the next power-off and power-on provided
that the error condition is cleared.
-
Off: System off / System OK.
Green
Blinking: Drive activity
-
Off: No drive activity
Green
Blinking: Linked and activity on the network
On: Linked to network
-
Off: LAN not connected
Blue
Blinking: Command trigger
On: Identification
-
Off: Disabled
Back View LEDs
Green
Blinking: Linked and activity on the network.
-
Off: No connection
GREEN
On: Linked to the network.
-
Off: No connection
Blue
Blinking: System is being remotely managed
On: Identification
-
Off: Disabled
Green
On: +12V is output
-
Off: No AC on or no main power on
Description
7

Advertisement

Table of Contents
loading

Table of Contents