Intel SR1630GPRX Service Manual
Intel SR1630GPRX Service Manual

Intel SR1630GPRX Service Manual

Table of Contents

Advertisement

Quick Links

®
Intel
Server System
SR1630GPRX/SR1630HGPRX
Service Guide
®
A Guide for Technically Qualified Assemblers of Intel
Identified Subassemblies/
Products
Intel Order Number E90835-002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR1630GPRX and is the answer not in the manual?

Questions and answers

Summary of Contents for Intel SR1630GPRX

  • Page 1 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide ® A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number E90835-002...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://www.intel.com/support/...
  • Page 4 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 5: Warnings

    Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 6: Preface

    BIOS update, and reset the password or CMOS. Information about the ® specific BIOS settings and screens is available in the Intel Server Board S3420GPRX Technical Product Specification. See the table below for a link to the Technical Product Specification.
  • Page 7: Product Contents

    The Intel Server System SR1630GPRX/SR1630HGPRX ships with the Intel Server Board S3420GPRX. ® There are two versions of this server system: the Intel Server System SR1630GPRX and ® the Intel Server System SR1630HGPRX. The contents of each server system are listed below.
  • Page 8: Intel ® Server System Sr1630Hgprx Contents

    — One front panel USB cable, installed in the server system — One front panel cable, installed in the server system — One SPGIO cable, installed in the server system. • Documentation, drivers, and installation CD ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 9: Server System References

    Accessories or other Intel Spares and Configuration Guide server products This is available from your Intel field representative or on the Server Configurator Tool at: http://indigo.intel.com/serverconfiguratortool/default.aspx Hardware (peripheral For the Tested Hardware Operating Systems List, you can go to the ®...
  • Page 10: Table Of Contents

    Preface ........................vii About this Manual ........................ vii Manual Organization ......................vii Product Contents .........................viii ® Intel Server System SR1630GPRX Contents ............viii ® Intel Server System SR1630HGPRX Contents ............ix Server System References ....................x Chapter 1: Server System Features ................1 Chassis Component Identification ..................
  • Page 11 Installing a Hot-Swap SATA Drive (SR1630HGPRX) ..........51 Removing a Hot-Swap SATA Drive (SR1630HGPRX) ..........53 Installing or Removing a Slimline Optical Drive (SR1630GPRX) ........54 Installing a Slimline Optical Drive ................54 Removing a Slimline Optical Drive ................56 Installing or Removing a Slimline Optical Drive (SR1630HGPRX) ........
  • Page 12 Replacing the CMOS Battery ....................75 Replacing the Power Supply (SR1630GPRX) ..............77 Replacing the Power Supply (SR1630HGPRX) ..............82 Replacing the Front Panel Board (SR1630GPRX) ..............84 Replacing the Front Panel Board (SR1630HGPRX) ............86 Replacing a System Fan (SR1630GPRX) ................90 Replacing the System Blower Fans (SR1630GPRX) ..........90 Replacing a System Fan (SR1630HGPRX) ................94...
  • Page 13 Consignes de sécurité sur le serveur ................ 137 Sécurité: avertissements et mises en garde ............. 137 Domaines d’utilisation prévus ................... 138 Sélection d’un emplacement ..................138 Pratiques de manipulation de l’équipement .............. 139 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 14 Korean Compliance (KCC) ..................166 End-of-Life / Product Recycling ..................166 Appendix F: Warranty .................... 167 ® Limited Warranty for Intel Chassis Subassembly Products ..........167 Appendix G: Getting Help ..................171 World Wide Web ........................171 Telephone ..........................171 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide xvii...
  • Page 15 ® xviii Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 16 Figure 27. Removing the Protective Socket Cover ..............42 Figure 28. Installing the Heat Sink ..................43 Figure 29. Removing Drive Carrier from the Server System (SR1630GPRX) ......45 Figure 30. Installing Drive into Drive Carrier (SR1630GPRX)..........46 Figure 31. Install Drive Assembly into the Server System (SR1630GPRX)......46 Figure 32.
  • Page 17 Figure 64. Removing Power Supply from the Server System (SR1630HGPRX) ....82 Figure 65. Installing Power Supply Module into the Server System (SR1630HGPRX) ..83 Figure 66. Removing Front Panel Board from the Server System (SR1630GPRX) ....84 Figure 67. Installing Front Panel Board into the Server System (SR1630GPRX) ....85 Figure 68.
  • Page 18 Table 1. Intel Server System SR1630GPRX/SR1630HGPRX Feature Summary ....3 ® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions ......6 ® Table 3. Intel Server System SR1630HGPRX Control Panel LED Functions ......8 Table 4. NIC LED Descriptions ....................9 Table 5.
  • Page 19: Chapter 1: Server System Features

    ® Figure 1. Intel Server System SR1630GPRX Note: Figure 1 is shown with an optional optical drive installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 20: Figure 2. Intel ® Server System Sr1630Hgprx

    ® Figure 2. Intel Server System SR1630HGPRX Note: Figure 2 is shown with an optional optical drive installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 21: Table 1. Intel ® Server System Sr1630Gprx/Sr1630Hgprx Feature Summary

    GB maximum with x8 ECC UDIMM (2 Gb DRAM) ® NOTE: Intel i3 Processor supports only UDIMMs ® • Chipset Support for Intel 3420 Chipset Platform Controller Hub (PCH) • PCI Express* switch - 89HI0524G2PS ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 22 Support for six Serial ATA II hard drives through six on-board Drive Support SATA II connectors with SW RAID 0, 1, 5, and 10. • Optical devices are supported ® • Up to four SAS hard drives through optional Intel SAS Entry RAID Module card • ® RAID Support Intel Embedded Server RAID Technology II through onboard SATA connectors provides SATA RAID 0, 1, and 10.
  • Page 23 Light-Guided Diagnostics on field replacable units • ® Support for Intel System Management Software 3.6.1 and beyond • ® Support for Intel Deployment Assistant 3.5.2 and beyond Form Factor ATX, 12” x 9.6”, 1U thermal optimized ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 24: Chassis Component Identification

    Power Button NIC2 LED Status LED NIC3 LED Power LED NIC4 LED HDD Activity LED NIC5 LED Figure 3. Front Controls and LEDs (SR1630GPRX) ® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions Color State Description NIC1 to NIC5...
  • Page 25 ® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions Color State Description System Green Running / normal operation Status (on Blink System ready, but degraded standby power) Amber Critical or non-recoverable condition. Possible critical power module failure, critical fan failure, voltage (power...
  • Page 26: System Front Panel (Sr1630Hgprx)

    Green Power on Sleep Blink Sleep / ACPI S1 state Power Off / ACPI S4 state System Status (on standby power) Disk Activity Green Random HDD access blink No hard disk drive activity ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 27: System Rear

    The following table provides the LED information. Table 4. NIC LED Descriptions LED State LED State NIC State Green LAN link is not established. LAN link is established. Blinking LAN activity is occurring. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 28 Table 4. NIC LED Descriptions LED State LED State NIC State 10 Mbit / sec data rate is selected Green 100 Mbit / sec data is selected Yellow 1000 Mbit / sec data rate is selected ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 29: Peripheral Devices (Sr1630Gprx)

    Note: Each drive can consume up to 17 W of power. Drives must be specified to run at a maximum ambient temperature of 45 ° ® Note: The Intel Server System SR1630GPRX/SR1630HGPRX does not support all Serial ATA (SATA) hard drives. See “Server System References” for an Internet link to a list of supported hardware.
  • Page 30: Slimline Optical Drive Carrier

    One slimline drive carrier is included with your server system; you must purchase the optical drive separately. To use the slimline DVD drive provided by Intel, use order code AXXSATADVDROM. To use the slimline DVD CDRW drive provided by Intel, use order code AXXSATADVDRWROM.
  • Page 31: Internal Components (Sr1630Gprx)

    System Memory DIMM Sockets Server Board System Blower Fans (two) Processor Air Duct Hard Drive Bays PCIe* Riser Assembly Front Panel Processor and Heatsink Slimline Optical Drive Bay Power Supply Figure 6. System Components (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 32: Internal Components (Sr1630Hgprx)

    System Blower Fans (two) Front Panel Processor Air Duct Hard Drive Carriers (two) Server Board Slimline Optical Drive Bay PCIe* Riser Assembly M. Hard Drive Carrier (one) Processor and Heat Sink Figure 7. System Components (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 33: Server Board Connectors / Components

    Server Board Connectors / Components ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 34: Figure 8. S3420Gprx Connector And Component Locations

    HH. Internal USB connector ® DIMM Slots II. Intel RMM3 Lite System FAN 3 JJ. Front Panel Connector System FAN 2 KK. Internal Serial Port CPU Socket Figure 8. S3420GPRX Connector and Component Locations ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 35: Configuration Jumpers

    J1F1 BIOS BIOS J1F2 J1F2 Recovery Recovery CMOS CMOS CMOS Clear Clear Clear Disable Disable Enable Enable Disable Disable Disable Enable Enable Enable J1F3 J1F3 J1F5 J1F5 J1F5 Figure 9. Configuration Jumper Descriptions ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 36: Hardware Requirements

    Server Board S3420GPRX supports one Intel Xeon 3400 processor series with 95 W Thermal Design Power (TDP). ® ® Intel Server Board S3420GPRX can also support Intel Core i3 processor. For a complete list of supported processors, see the links under “Server System References”. Memory ®...
  • Page 37 DIMM timings (RAS latency, CAS latency, etc.). ® ® The Intel SAS Entry RAID Module option is enabled by default once the Intel Entry RAID Module. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 38 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 39: Chapter 2: Server Utilities

    You can run BIOS Setup with or without an operating system ® present. See the links under “Server System References” for a link to the Intel Server Board S3420GPRX Technical Product Specification where you will find details about specific BIOS setup screens.
  • Page 40: Table 6. Setup Menu Key Use

    If “No” is selected and <Enter> is pressed, or <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 41: Upgrading The Bios

    Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip Step 2. You need these settings to configure your server at the end of the procedure. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 42: Upgrading The Bios

    1. Power down and unplug the system from the AC power source. 2. Move the recovery jumper at JIF3 from the spare location at pins 2 and 3 to cover pins 1 and 2. Refer to the following figure. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 43: Clearing The Password

    “clear” position clears both passwords. Before a new password(s) is set, you must restore the password clear jumper to its original position. 1. Power down the system and disconnect the AC power. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 44: Clearing The Cmos

    2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset / clear position (covering pins 2 and 3). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 45: Updating The Integrated Bmc

    Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the Integrated BMC firmware update process fails (due to the Integrated BMC not being in the proper update state), the server ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 46 9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 47: Chapter 3: Hardware Installations And Upgrades

    Server System SR1630HGPRX are hot-swappable and are noted as such (where applicable) in the following instructions. ® Note: Most of the illustrations in this chapter show the Intel Server System SR1630GPRX with an optional optical drive installed. Unless otherwise noted, the instructions for removing ®...
  • Page 48: Removing And Installing The Server Cover

    2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord. 4. SR1630GPRX: Remove the two screws at the front of the chassis. See letter “A” in Figure 14. 5. SR1630GPRX: Loosen the screw at the rear of the chassis. See letter “B” in Figure 14.
  • Page 49: Figure 15. Removing The Server System Cover (Sr1630Hgprx)

    8. SR1630HGPRX: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “B” in Figure 15. AF001578 Figure 15. Removing the Server System Cover (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 50: Installing The Server System Cover

    1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. 2. SR1630GPRX: Place the cover over the server system so that the side edges of the cover sit just inside the server system sidewalls. Slide the cover forward. See letter “A” in Figure 16.
  • Page 51: Removing And Installing The Processor Air Duct

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 18 for SR1630GPRX; see Figure 19 for SR1630HGPRX). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 52: Figure 18. Removing The Processor Air Duct (Sr1630Gprx)

    AF003364 Figure 18. Removing the Processor Air Duct (SR1630GPRX) AF003365 Figure 19. Removing the Processor Air Duct (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 53: Installing The Processor Air Duct

    5. Install the server system cover. For instructions, see “Installing the Server System Cover”. AF003366 Figure 20. Installing the Processor Air Duct (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 54: Installing And Removing Memory

    DIMM B2 starting from the center of the board. See “Memory” for a discussion of the memory requirements and options. See “Server System References” for a link to the list of tested DIMMs. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 55: Installing Dimms

    11. Install the server system cover. For instructions, see “Installing the Server System Cover”. Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 56 6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 57: Replacing The Processor

    8. Raise the CPU load plate. 9. Remove the processor. 10. If installing a replacement processor, see “Installing the Processor”. Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 58: Installing The Processor

    Figure 23. Lifting the Processor Socket Handle 5. Push the rear tab with your finger to slightly lift the front of the load plate. Raise the load plate completely. Raise the CPU load plate (see Figure 24). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 59: Figure 24. Opening The Load Plate

    Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 6. Remove the processor from the packaging box and remove the protective shipping cover. See Figure 25. AF003189 Figure 25. Removing the Shipping Cover ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 60: Figure 26. Installing The Processor

    9. Remove the protective socket cover. See Figure AF003368 Figure 27. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 61: Installing The Heat Sink

    Figure 28. Do not fully tighten one screw before tightening another. 5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened. AF003369 Figure 28. Installing the Heat Sink ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 62: Installing And Removing A Hard Drive (Sr1630Gprx)

    Internet link to a list of supported hardware. Installing a Hard Disk Drive (SR1630GPRX) Note: If you are replacing a hard drive, see “Removing a Hard Disk Drive (SR1630GPRX)” on page 48 for instructions first. Return to these steps when directed.
  • Page 63: Figure 29. Removing Drive Carrier From The Server System (Sr1630Gprx)

    AF001050 Figure 29. Removing Drive Carrier from the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 64: Figure 30. Installing Drive Into Drive Carrier (Sr1630Gprx)

    “C” in Figure 31. Note: You must install the assembly that contains the optical drive bracket at the left side of the system. AF003392 Figure 31. Install Drive Assembly into the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 65 Figure — Letter “B”: If a drive is installed in the HDD0 carrier, attach the middle connector on the daisy chain power cable to the HDD0 power connector. See letter “D” in Figure ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 66: Removing A Hard Disk Drive (Sr1630Gprx)

    AF003254 Figure 32. Connecting Hard Drive Power and Data Cables (SR1630GPRX) 17. Install the server system cover. For instructions, see “Installing the Server System Cover”. Removing a Hard Disk Drive (SR1630GPRX) 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety...
  • Page 67: Figure 33. Removing Drive Carrier From The Server System (Sr1630Gprx)

    7. Lift the drive carrier from the chassis. See letter “B” in Figure 33. AF001050 Figure 33. Removing Drive Carrier from the Server System (SR1630GPRX) 8. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier.
  • Page 68 Note: You must install the assembly that contains the optical drive bracket at the left side of the system. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 69: Installing And Removing A Hot-Swap Sata Drive (Sr1630Hgprx)

    Internet link to a list of supported hardware. Installing a Hot-Swap SATA Drive (SR1630HGPRX) 1. . Locate the drive position you want to use. See Figure AF003391 Figure 34. Locating Drive Positions (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 70: Figure 35. Removing The Drive Carrier (Sr1630Hgprx)

    8. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device. See letter “B” in Figure 36. AF001584 Figure 36. Installing Drive into Drive Carrier (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 71: Removing A Hot-Swap Sata Drive (Sr1630Hgprx)

    Note: For proper airflow, you must replace the hard drive carrier in the server system, even if no hard drive is installed in it. 7. When the black lever begins to close by itself, push on it to lock the drive carrier into place. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 72: Installing Or Removing A Slimline Optical Drive (Sr1630Gprx)

    4. First time installation only: Remove the knock-out by rocking it back and forth. See letter “A” in Figure 38. You cannot reinstall the knock-out. AF001174 Figure 38. Removing the Knock-out from the Sheet Metal Panel ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 73: Figure 39. Attaching The Optical Drive To The Brackets

    8. Connect the mini SATA power connector on the optical drive. 9. Connect the data cable to the optical drive and to the SATA connector on the server board. AF003257 Figure 40. Installing the Optical Drive into the System ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 74: Removing A Slimline Optical Drive

    Figure 41. Removing the Optical Drive from the Server System 7. Remove the four screws that hold the optical drive to the brackets as shown in Figure 42. Save these screws for future use. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 75: Installing Or Removing A Slimline Optical Drive (Sr1630Hgprx)

    “CD-ROM Assy”. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 76: Figure 43. Attaching The Optical Drive To The Attachment Bracket

    7. Install the screws to lock the drive in place (see letters “B” and “C” in Figure 44). AF001636 Figure 44. Installing the Optical Drive into the System 8. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 77: Removing A Slimline Optical Drive (Sr1630Hgprx)

    5. Remove the optical drive attachment bracket as shown in Figure 46. Figure 46. Removing the Optical Drive from the Attachment Bracket 6. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 78: Installing And Removing The Pcie* Riser Assembly

    5. Lift riser assembly up to remove it. Use caution to gently ease the riser card from the add-in card slot so you do not damage the slot or the riser card. See Figure Riser Socket AF003393 Figure 47. Removing PCIe* Riser Assembly from the Server System ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 79: Installing The Pcie* Riser Assembly

    The riser cards will seat into the matching sockets on the server board. 4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 80: Installing Or Replacing A Pcie* Riser Card

    Card”. 7. Remove the screw that attaches the riser card to the riser assembly. See Figure 49. Save these screws to be used later. AF003288 Figure 49. Removing Riser Card from Riser Assembly ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 81: Installing A Pcie* Riser Card

    10. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 11. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 82: Installing And Removing A Pci Add-In Card

    2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 83: Removing A Pci Add-In Card

    2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 84: Figure 52. Removing A Full Height Add-In Card

    10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 85: Installing And Removing The I/O Expansion Module

    6. First fit the front of the module into the back panel slot(s), and then attach the module to the server board connector and engage the standoffs (see letter “C” in Figure 53). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 86: Removing The I/O Expansion Module

    4. Remove the standoffs from the server board (see letter “B” in Figure 54). 5. Install the I/O expansion module filler panel(s) into the system back panel (see letter “C” in Figure 54). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 87: Figure 54. Removing The I/O Expansion Module From The Server System

    Figure 54. Removing the I/O Expansion Module from the Server System 6. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 7. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 88: Installing And Removing The Rmm3 Lite

    Removing the RMM3 Lite 1. Remove the PCI riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. 2. Disconnect the RMM3 Lite from the server board RMM3 Lite connector (J2D1) as shown in Figure ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 89: Figure 56. Removing The Rmm3 Lite To The Server System

    Figure 56. Removing the RMM3 Lite to the Server System 3. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 90: Replacing The Server Board

    6. Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see “Removing the Heat Sink and Processor”. 8. Remove the DIMMs. For instructions, see “Removing DIMMs”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 91: Figure 57. Removing The Server Board

    15. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 16. Install the server system cover. For instructions, see “Installing the Server System Cover”. 17. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 92: Installing The Server Board

    6. Place the server board into the server system as shown by letter “A” in Figure 58. 7. Attach the server board with nine screws. See letter “B” in Figure 58. AF003374 Figure 58. Installing the Server Board ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 93: Replacing The Cmos Battery

    Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 94: Figure 59. Replacing The Cmos Battery

    8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 95: Replacing The Power Supply (Sr1630Gprx)

    Replacing the Power Supply (SR1630GPRX) Caution: The power supply is NOT hot-swappable. Before removing or replacing the power supply, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
  • Page 96: Figure 60. Disconnecting Power Cables (Sr1630Gprx)

    Optical Device HDD 0 HDD 1 AF003376 Figure 60. Disconnecting Power Cables (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 97: Figure 61. Removing Power Supply From The Server System (Sr1630Gprx)

    Save this screw. You will re-insert it later. See letter “A” in Figure 61. 6. Remove both the screws and lift up the power supply. See letter "B" in Figure AF003395 Figure 61. Removing Power Supply from the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 98: Figure 62. Installing Power Supply Module Into The Server System (Sr1630Gprx)

    8. Set the front of the power supply down by pushing the power supply back. Insert and fasten the three screws you removed in Step 5 and Step 6. AF003396 Figure 62. Installing Power Supply Module into the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 99: Figure 63. Connecting Power Cables (Sr1630Gprx)

    Optical Device HDD 0 HDD 1 AF003376 Figure 63. Connecting Power Cables (SR1630GPRX) 10. Install the server system cover. For instructions, see “Installing the Server System Cover”. 11. Plug all peripheral devices and the AC power cable into the server.
  • Page 100: Replacing The Power Supply (Sr1630Hgprx)

    3. Disconnect all power cables connected to the server board and peripherals. 4. Remove both the screws and lift up the power supply. See letter "B" in Figure 64. AF003377 Figure 64. Removing Power Supply from the Server System (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 101: Figure 65. Installing Power Supply Module Into The Server System (Sr1630Hgprx)

    See letter “A” in Figure 65. 8. Connect the power supply cables to the server board and peripherals. 9. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 102: Replacing The Front Panel Board (Sr1630Gprx)

    Replacing the Front Panel Board (SR1630GPRX) Caution: The front panel is NOT hot-swappable. Before removing or replacing the front panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
  • Page 103: Figure 67. Installing Front Panel Board Into The Server System (Sr1630Gprx)

    Figure 67. Installing Front Panel Board into the Server System (SR1630GPRX) 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 104: Replacing The Front Panel Board (Sr1630Hgprx)

    6. Slide the front panel board back (see letter “B” in Figure 68) and lift the front panel board from the system (see letter “C” in Figure 68). AF003383 Figure 68. Removing Front Panel Board from the Server System (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 105: Figure 69. Removing Light Pipes From The Front Panel Board (Sr1630Hgprx)

    (see letter “B” in Figure 70). 9. Use the screw you removed in Step 5 to attach the front panel board to the system (see letter “C” in Figure 70). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 106: Figure 70. Installing Front Panel Board Into The Server System (Sr1630Hgprx)

    AF003385 Figure 70. Installing Front Panel Board into the Server System (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 107: Figure 71. Installing Light Pipes On The Front Panel Board (Sr1630Hgprx)

    12. Connect the front panel cable. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 108: Replacing A System Fan (Sr1630Gprx)

    5. Disconnect the two fan cables from the server board (see letter “B” in Figure 72) and untie the cable tie (see letter “C” in Figure 72). AF003275 Figure 72. Disconnecting System Blower Fans (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 109: Figure 73. Removing Bracket And System Blower Fans From Server System (Sr1630Gprx)

    8. Lift the fan bracket from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter “C” in Figure 73. AF003276 Figure 73. Removing Bracket and System Blower Fans from Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 110: Figure 74. Removing Fan From Fan Bracket (Sr1630Gprx)

    Figure 74. 10. Lift the fan from the bracket. See letter “B” in Figure 74. AF000963 Figure 74. Removing Fan from Fan Bracket (SR1630GPRX) 11. Install the replacement fan onto the bracket, using the two screws you removed in Step 9.
  • Page 111: Figure 75. Connecting System Blower Fans (Sr1630Gprx)

    14. Connect the fans to the server board. See letters “A” and “B” in Figure 75. AF003277 Figure 75. Connecting System Blower Fans (SR1630GPRX) 15. Install the processor air duct. For instructions. see “Installing the Processor Air Duct”. ® Intel...
  • Page 112: Replacing A System Fan (Sr1630Hgprx)

    5. Remove the two screws that hold the fan in place. Save these screws. You will re- install them later. 6. Disconnect the fan cable from the server board (see letter “B” in Figure 76). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 113: Figure 76. Removing Fan From The Server System (Sr1630Hgprx)

    8. Install the replacement fan into the chassis (see letter “A” in Figure 77), using the two screws you removed previously. 9. Connect the fan cable to the server board (see letter “B” in Figure 77). 10. Install the processor air duct (see letter “C” in Figure 77). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 114: Installing And Removing The Rack Handles

    Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Attach the rack handle to the server system with two screws as shown in Figure 78. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 115: Figure 78. Installing The Rack Handle

    AF001204 Figure 78. Installing the Rack Handle 4. Repeat Step 3 on the opposite side of the server. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 116: Removing The Rack Handles

    Figure 79. AF001204 Figure 79. Removing the Rack Handle 4. Repeat Step 4 on the opposite side of the system. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 117: Appendix A: Technical Reference

    For example, the PCI cooling fan cable is labeled with the letter “C” both where it connects to the server board and at the PCI cooling fan itself. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 118: Cable Routing (Sr1630Gprx)

    SATA-0 Front Panel location. System Fan Blower Power ... left fan System Fan Blower Power ... right fan Power to Server Board (Main) AF003389 Figure 80. Data Cable Routing (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 119: Cable Routing (Sr1630Hgprx)

    Link to backplane SPGIO Optical Drive to Power Supply Sys fan Power PSU management bus to AUX Server Board SATA Connector Legend Begin cable connections at the SATA-0 location. AF003390 Figure 81. Cable Routing (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 120: 350-W Single Power Supply Input Voltages

    “Calculating Power Usage”. Table 7. Power Supply Output Capability Voltage Maximum Current +3.3 V 6.8 A +5.0 V 10.9 A +5 V Standby 1.9 A +12.0 10.8 A -12.0 V 0.4 A ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 121: System Environmental Specifications

    7 Bels in sound power for a typical office ambient temperature (65 to 75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 8 Kilovotls (KV) contact discharge, 12 kilovolts (KV) air discharge; discharge (ESD) no component damage. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 122 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 123: Appendix B: Troubleshooting

    SATA drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References”...
  • Page 124: Problems Following Initial System Installation

    See “Server System References” for links to the tested component lists. Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 125: Verifying Proper Operation Of Key System Lights

    • Characters on the screen appear distorted or incorrect. • System cooling fans do not rotate. • Diskette drive activity light does not light. • Hard disk drive activity light does not light. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 126: Power Light Does Not Light

    Are the brightness and contrast controls on the video monitor properly adjusted? • Is the video monitor signal cable properly installed? • Does this video monitor work correctly if plugged into a different system? ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 127: Characters Are Distorted Or Incorrect

    If the system cooling fans are not operating properly, it is an indication of possible system component failure. Check the following: • Is the power-on light lit? If not, see “Power Light Does Not Light”. • Are any other front panel LEDs lit? ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 128: Drive Activity Light Does Not Light

    Make sure the driver is loaded and the protocols are bound. • Make sure the hub port is configured for the same duplex mode as the network controller. • Make sure the correct networking software is installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 129: Problems With Network

    Before installing a PCI card, you should always: • Turn off the server power by using the power button on the front of the system. • Unplug the AC power cord(s) from the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 130: Problems With Newly Installed Application Software

    If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 131: Devices Are Not Recognized Under Device Manager (Microsoft Windows* Operating System)

    Devices are not Recognized under Device Manager (Microsoft Windows* Operating System) ® The Microsoft Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Server System References” for a link to the current drivers and chipset files.
  • Page 132: Led Information

    BIOS beep codes. Table 11. POST Error Beep Codes Number of Reason for Beeps and Action to Take Beeps System halted because a fatal error related to the memory was detected. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 133: Appendix C: Installation/Assembly Safety Instructions

    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 134 Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Dispose of used batteries according to manufacturer's instructions. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 135: Deutsch

    Netzgerät ein eigenes Netzkabel. Der Wechselstrom des Systems wird durch den Ein-/Aus-Schalter für Gleichstrom nicht ausgeschaltet. Ziehen Sie jedes Wechselstrom-Netzkabel aus der Steckdose bzw. dem Netzgerät, um den Stromanschluß des Systems zu unterbrechen. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 136 4. Bringen Sie die Verschlußeinrichtung (Padlock) wieder an und schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. 5. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 137: Français

    Français Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plus d'un bloc d'alimentation. Veuillez contacter un technicien qualifié en cas de problème. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 138 Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 139 • "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 140: Español

    - o a cualquier tipo de superficie de metal sin pintar. 6. No ponga en marcha el sistema si se han extraído las tapas del chasis. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 141 Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 142 • "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 143: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 144 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 145: Appendix D: Safety Information

    Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored. Indicates potential hazard if indicated information is ignored. Indicates shock hazards that result in serious injury or death if safety instructions are not followed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 146: Intended Application Uses

    Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of personal injury or equipment damage: ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 147: Power And Electrical Warnings

    Disconnect all cables and telecommunication lines that are connected to the compute module. • Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 148: Electrostatic Discharge (Esd)

    Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 149: Deutsch

    Komponenten, die im vorliegenden Handbuch angegeben werden. Die Verwendung anderer Produkte oder Komponenten führt zum Erlöschen der UL-Zulassung und anderer Genehmigungen für das Produkt. Dadurch kann das Produkt gegen Produktbestimmungen verstoßen, die im Verkaufsland gelten. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 150: Sicherheitshinweise Und Vorsichtsmaßnahmen

    Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 151: Standortauswahl

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 152: Warnungen Zu Netzspannung Und Elektrizität

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 153: Elektrostatische Entladungen (Esd)

    Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 154: Andere Gefahren

    • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 155: Français

    Français Consignes de sécurité sur le serveur ® ® Ce document s’applique aux cartes serveur Intel , au châssis de serveur (sur pieds et Intel sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre...
  • Page 156: Domaines D'utilisation Prévus

    Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 157: Pratiques De Manipulation De L'équipement

    • Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 158: Alimentation Et Avertissements En Matière D'électricité

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 159: Décharges Électrostatiques (Esd)

    Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en marche que lorsque les panneaux du châssis sont en place. L’utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux : ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 160: Español

    Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
  • Page 161: Aplicaciones Y Usos Previstos

    Es posible que sea necesario llevar a cabo una evaluación adicional para comprobar si este producto es apropiado para otras categorías de productos y entornos además de las aplicaciones informáticas (por ejemplo, soluciones médicas, industriales, residenciales, sistemas de alarma y equipos de pruebas). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 162: Selección De La Ubicación

    CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al ®...
  • Page 163: Advertencias El Acceso Al Sistema

    A no ser que esté instalando o extrayendo un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 164: Descarga Electrostática (Esd)

    Para instalar las cubiertas: • Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 165 Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 166 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 167 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 168 (ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE 应用的其他产品种类和环境(如医疗、工业、住宅、报警系统和测试设备)的适用性尚有待进 一步的评估。 场地选择 本系统专为在典型办公环境运行而设计。请选择符合以下条件的地点: 清洁、干燥,无气载微粒(而非一般的室内尘埃)。 通风良好,远离热源(包括直接日晒和散热器)。 远离振动源或物理震动。 与电气设备产生的强大电磁场隔离。 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信线路与调 制解调器之间的连接。 提供正确接地的墙壁插座。 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: 移举设备时遵守当地的职业健康与安全要求。 借助机械手段或其他合适的手段移举设备。 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接通电源,就 存在 5V 待机电源。要从系统切断电源,须从墙壁电源插座中拔下交流电线。您的系统可能不止使用一 根交流电线。请确保所有的交流电线都已拔下。打开机箱或增加或去除任何热插拔组件之前, 确保交流电线已拔下。 若非所需的确切类型,请勿尝试修改或使用交流电线。系统的每个电源供应设备都需要一根单 独的交流电线。 本产品的电源供应设备包含非用户维修部件。请勿打开电源供应设备。电源供应设备包含非常 危险的电压级、电流级和能量级。请与生产商联系维修事宜。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,再将其从服务器上 移除。 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 169 为避免电击,请在打开服务器之前,关闭服务器并断开服务器上连接的电源线、电信系统、网 络和调制解调器。 电源线警告 如果产品未提供交流电线,请购买一根您所在国家批准使用的交流电线。 注意事项 为避免电击或火灾危险,请按如下所述对产品所用的电源线进行检查: 若非所需的符合接地插座的确切类型,请勿尝试修改或使用交流电线 电源线须符合以下标准: 电源线的电气额定值须大于产品上标注的电流额定值。 电源线须拥有适合插座的安全接地插头或触点。 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: 关闭所有与本产品相连的外设。 按下电源按钮至关闭状态,关闭系统。 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 断开与系统相连的所有线缆和通信线路。 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请用螺钉或紧 固件重新固定舱口盖。 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系维修事宜. 增加或替换任何非热插拔组件之前,请关闭服务器电源并断开所有电源线。 替换热插拔电源供应设备时,请先拔下需替换的电源供应设备上的电源线,然后再从 服务器上移除电源供应设备。 注意事项 如果服务器一直在运行,任何已安装的处理器和吸热设备都可能很热。除非要增加或移除热插 拔组件,否则请待系统冷却后再开盖。为避免在热插拔组件安装过程中接触灼热组件,移除或 安装热插拔组件时务须小心。 注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸下风机防护 装置运行系统。 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 170 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机架生产商提 供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且须标明为控 制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地或任何未喷 漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将主板组件侧 面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要使用主板包装。请勿将 主板在任何表面上滑动。 其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 171 为 避免 幅射 暴露 和 / 或 人身伤 害: 请 勿打 开任 何激 光外 设或 激光 设备 的外 壳 激 光外 设或 激光 设备 为非 用户 维修 设备 请 与生 产商 联系 维修 事宜 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 172 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 173: Appendix E: Regulatory And Compliance Information

    (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 174: Product Emc Compliance - Class A Compliance

    This server system has been tested and verified to comply with the following ® electromagnetic compatibility (EMC) regulations when installed in a compatible Intel host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. ®...
  • Page 175: Product Ecology Requirements

    Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
  • Page 176 — CE DOC (Europe) — CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply. Power supply to comply with the Intel power supply specification. • Peripheral Devices (e.g. Disk Drives, CD ROMs) —...
  • Page 177: Certifications / Registrations / Declarations

    GOST R Certification / License (Russia) • KCC Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 178: Table 12. .Product Regulatory Compliance Markings

    Ctick Mark Australia / NZ N232 CANADA ICES-003 CLASS A EMC Marking Canada CE Mark Europe GS Mark Germany VCCI Mark Japan KCC Mark Korea 인증번호 : CPU-SR1630 (A) GOST Mark Russia ME06 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 179 “Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.” Finnish on line 3: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.” English on line 4: “Connect only to a properly earth grounded outlet.” ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 180 Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. WEEE WEEE Marking Marking China RoHS China RoHS China Recycling Package China Recycling Marks Package Marks Will be added on Package label. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 181 Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. Standard icon for Power button Should be attached on power button ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 182: Electromagnetic Compatibility Notices

    All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 183: Industry Canada (Ices-003)

    Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 184: Bsmi (Taiwan)

    Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
  • Page 185: Appendix F: Warranty

    "as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 186: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 187: How To Obtain Warranty Service

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 188 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 189: Appendix G: Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an Intel Server Issue Report Form.
  • Page 190 Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
  • Page 191 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...