Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit CD and/or at http://www.intel.com/support/...
Page 4
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
BIOS update, and reset the password or CMOS. Information about the ® specific BIOS settings and screens is available in the Intel Server Board S3420GPRX Technical Product Specification. See the table below for a link to the Technical Product Specification.
The Intel Server System SR1630GPRX/SR1630HGPRX ships with the Intel Server Board S3420GPRX. ® There are two versions of this server system: the Intel Server System SR1630GPRX and ® the Intel Server System SR1630HGPRX. The contents of each server system are listed below.
— One front panel USB cable, installed in the server system — One front panel cable, installed in the server system — One SPGIO cable, installed in the server system. • Documentation, drivers, and installation CD ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Accessories or other Intel Spares and Configuration Guide server products This is available from your Intel field representative or on the Server Configurator Tool at: http://indigo.intel.com/serverconfiguratortool/default.aspx Hardware (peripheral For the Tested Hardware Operating Systems List, you can go to the ®...
Preface ........................vii About this Manual ........................ vii Manual Organization ......................vii Product Contents .........................viii ® Intel Server System SR1630GPRX Contents ............viii ® Intel Server System SR1630HGPRX Contents ............ix Server System References ....................x Chapter 1: Server System Features ................1 Chassis Component Identification ..................
Page 11
Installing a Hot-Swap SATA Drive (SR1630HGPRX) ..........51 Removing a Hot-Swap SATA Drive (SR1630HGPRX) ..........53 Installing or Removing a Slimline Optical Drive (SR1630GPRX) ........54 Installing a Slimline Optical Drive ................54 Removing a Slimline Optical Drive ................56 Installing or Removing a Slimline Optical Drive (SR1630HGPRX) ........
Page 12
Replacing the CMOS Battery ....................75 Replacing the Power Supply (SR1630GPRX) ..............77 Replacing the Power Supply (SR1630HGPRX) ..............82 Replacing the Front Panel Board (SR1630GPRX) ..............84 Replacing the Front Panel Board (SR1630HGPRX) ............86 Replacing a System Fan (SR1630GPRX) ................90 Replacing the System Blower Fans (SR1630GPRX) ..........90 Replacing a System Fan (SR1630HGPRX) ................94...
Page 13
Consignes de sécurité sur le serveur ................ 137 Sécurité: avertissements et mises en garde ............. 137 Domaines d’utilisation prévus ................... 138 Sélection d’un emplacement ..................138 Pratiques de manipulation de l’équipement .............. 139 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 14
Korean Compliance (KCC) ..................166 End-of-Life / Product Recycling ..................166 Appendix F: Warranty .................... 167 ® Limited Warranty for Intel Chassis Subassembly Products ..........167 Appendix G: Getting Help ..................171 World Wide Web ........................171 Telephone ..........................171 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide xvii...
Page 15
® xviii Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 16
Figure 27. Removing the Protective Socket Cover ..............42 Figure 28. Installing the Heat Sink ..................43 Figure 29. Removing Drive Carrier from the Server System (SR1630GPRX) ......45 Figure 30. Installing Drive into Drive Carrier (SR1630GPRX)..........46 Figure 31. Install Drive Assembly into the Server System (SR1630GPRX)......46 Figure 32.
Page 17
Figure 64. Removing Power Supply from the Server System (SR1630HGPRX) ....82 Figure 65. Installing Power Supply Module into the Server System (SR1630HGPRX) ..83 Figure 66. Removing Front Panel Board from the Server System (SR1630GPRX) ....84 Figure 67. Installing Front Panel Board into the Server System (SR1630GPRX) ....85 Figure 68.
Page 18
Table 1. Intel Server System SR1630GPRX/SR1630HGPRX Feature Summary ....3 ® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions ......6 ® Table 3. Intel Server System SR1630HGPRX Control Panel LED Functions ......8 Table 4. NIC LED Descriptions ....................9 Table 5.
® Figure 1. Intel Server System SR1630GPRX Note: Figure 1 is shown with an optional optical drive installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
® Figure 2. Intel Server System SR1630HGPRX Note: Figure 2 is shown with an optional optical drive installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
GB maximum with x8 ECC UDIMM (2 Gb DRAM) ® NOTE: Intel i3 Processor supports only UDIMMs ® • Chipset Support for Intel 3420 Chipset Platform Controller Hub (PCH) • PCI Express* switch - 89HI0524G2PS ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 22
Support for six Serial ATA II hard drives through six on-board Drive Support SATA II connectors with SW RAID 0, 1, 5, and 10. • Optical devices are supported ® • Up to four SAS hard drives through optional Intel SAS Entry RAID Module card • ® RAID Support Intel Embedded Server RAID Technology II through onboard SATA connectors provides SATA RAID 0, 1, and 10.
Page 23
Light-Guided Diagnostics on field replacable units • ® Support for Intel System Management Software 3.6.1 and beyond • ® Support for Intel Deployment Assistant 3.5.2 and beyond Form Factor ATX, 12” x 9.6”, 1U thermal optimized ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Power Button NIC2 LED Status LED NIC3 LED Power LED NIC4 LED HDD Activity LED NIC5 LED Figure 3. Front Controls and LEDs (SR1630GPRX) ® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions Color State Description NIC1 to NIC5...
Page 25
® Table 2. Intel Server System SR1630GPRX Control Panel LED Functions Color State Description System Green Running / normal operation Status (on Blink System ready, but degraded standby power) Amber Critical or non-recoverable condition. Possible critical power module failure, critical fan failure, voltage (power...
Green Power on Sleep Blink Sleep / ACPI S1 state Power Off / ACPI S4 state System Status (on standby power) Disk Activity Green Random HDD access blink No hard disk drive activity ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
The following table provides the LED information. Table 4. NIC LED Descriptions LED State LED State NIC State Green LAN link is not established. LAN link is established. Blinking LAN activity is occurring. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 28
Table 4. NIC LED Descriptions LED State LED State NIC State 10 Mbit / sec data rate is selected Green 100 Mbit / sec data is selected Yellow 1000 Mbit / sec data rate is selected ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Note: Each drive can consume up to 17 W of power. Drives must be specified to run at a maximum ambient temperature of 45 ° ® Note: The Intel Server System SR1630GPRX/SR1630HGPRX does not support all Serial ATA (SATA) hard drives. See “Server System References” for an Internet link to a list of supported hardware.
One slimline drive carrier is included with your server system; you must purchase the optical drive separately. To use the slimline DVD drive provided by Intel, use order code AXXSATADVDROM. To use the slimline DVD CDRW drive provided by Intel, use order code AXXSATADVDRWROM.
System Memory DIMM Sockets Server Board System Blower Fans (two) Processor Air Duct Hard Drive Bays PCIe* Riser Assembly Front Panel Processor and Heatsink Slimline Optical Drive Bay Power Supply Figure 6. System Components (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
System Blower Fans (two) Front Panel Processor Air Duct Hard Drive Carriers (two) Server Board Slimline Optical Drive Bay PCIe* Riser Assembly M. Hard Drive Carrier (one) Processor and Heat Sink Figure 7. System Components (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
HH. Internal USB connector ® DIMM Slots II. Intel RMM3 Lite System FAN 3 JJ. Front Panel Connector System FAN 2 KK. Internal Serial Port CPU Socket Figure 8. S3420GPRX Connector and Component Locations ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Server Board S3420GPRX supports one Intel Xeon 3400 processor series with 95 W Thermal Design Power (TDP). ® ® Intel Server Board S3420GPRX can also support Intel Core i3 processor. For a complete list of supported processors, see the links under “Server System References”. Memory ®...
Page 37
DIMM timings (RAS latency, CAS latency, etc.). ® ® The Intel SAS Entry RAID Module option is enabled by default once the Intel Entry RAID Module. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 38
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
You can run BIOS Setup with or without an operating system ® present. See the links under “Server System References” for a link to the Intel Server Board S3420GPRX Technical Product Specification where you will find details about specific BIOS setup screens.
If “No” is selected and <Enter> is pressed, or <Esc> is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip Step 2. You need these settings to configure your server at the end of the procedure. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
1. Power down and unplug the system from the AC power source. 2. Move the recovery jumper at JIF3 from the spare location at pins 2 and 3 to cover pins 1 and 2. Refer to the following figure. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
“clear” position clears both passwords. Before a new password(s) is set, you must restore the password clear jumper to its original position. 1. Power down the system and disconnect the AC power. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset / clear position (covering pins 2 and 3). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Integrated BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the Integrated BMC firmware update process fails (due to the Integrated BMC not being in the proper update state), the server ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 46
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Server System SR1630HGPRX are hot-swappable and are noted as such (where applicable) in the following instructions. ® Note: Most of the illustrations in this chapter show the Intel Server System SR1630GPRX with an optional optical drive installed. Unless otherwise noted, the instructions for removing ®...
2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord. 4. SR1630GPRX: Remove the two screws at the front of the chassis. See letter “A” in Figure 14. 5. SR1630GPRX: Loosen the screw at the rear of the chassis. See letter “B” in Figure 14.
8. SR1630HGPRX: Push rearward on the blue grip point at the front of the server. Slide the cover back until it stops and then lift the cover upward to remove it. See letter “B” in Figure 15. AF001578 Figure 15. Removing the Server System Cover (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. 2. SR1630GPRX: Place the cover over the server system so that the side edges of the cover sit just inside the server system sidewalls. Slide the cover forward. See letter “A” in Figure 16.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two system blower fans (see Figure 18 for SR1630GPRX; see Figure 19 for SR1630HGPRX). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
AF003364 Figure 18. Removing the Processor Air Duct (SR1630GPRX) AF003365 Figure 19. Removing the Processor Air Duct (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
5. Install the server system cover. For instructions, see “Installing the Server System Cover”. AF003366 Figure 20. Installing the Processor Air Duct (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
DIMM B2 starting from the center of the board. See “Memory” for a discussion of the memory requirements and options. See “Server System References” for a link to the list of tested DIMMs. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
11. Install the server system cover. For instructions, see “Installing the Server System Cover”. Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 56
6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package. 7. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Raise the CPU load plate. 9. Remove the processor. 10. If installing a replacement processor, see “Installing the Processor”. Otherwise, install the protective socket cover over the empty processor socket and then reinstall the chassis cover. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 23. Lifting the Processor Socket Handle 5. Push the rear tab with your finger to slightly lift the front of the load plate. Raise the load plate completely. Raise the CPU load plate (see Figure 24). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 6. Remove the processor from the packaging box and remove the protective shipping cover. See Figure 25. AF003189 Figure 25. Removing the Shipping Cover ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
9. Remove the protective socket cover. See Figure AF003368 Figure 27. Removing the Protective Socket Cover Note: Retain the protective socket cover for use when removing a processor that will not be replaced. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 28. Do not fully tighten one screw before tightening another. 5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened. AF003369 Figure 28. Installing the Heat Sink ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Internet link to a list of supported hardware. Installing a Hard Disk Drive (SR1630GPRX) Note: If you are replacing a hard drive, see “Removing a Hard Disk Drive (SR1630GPRX)” on page 48 for instructions first. Return to these steps when directed.
“C” in Figure 31. Note: You must install the assembly that contains the optical drive bracket at the left side of the system. AF003392 Figure 31. Install Drive Assembly into the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 65
Figure — Letter “B”: If a drive is installed in the HDD0 carrier, attach the middle connector on the daisy chain power cable to the HDD0 power connector. See letter “D” in Figure ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
AF003254 Figure 32. Connecting Hard Drive Power and Data Cables (SR1630GPRX) 17. Install the server system cover. For instructions, see “Installing the Server System Cover”. Removing a Hard Disk Drive (SR1630GPRX) 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety...
7. Lift the drive carrier from the chassis. See letter “B” in Figure 33. AF001050 Figure 33. Removing Drive Carrier from the Server System (SR1630GPRX) 8. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier.
Page 68
Note: You must install the assembly that contains the optical drive bracket at the left side of the system. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Internet link to a list of supported hardware. Installing a Hot-Swap SATA Drive (SR1630HGPRX) 1. . Locate the drive position you want to use. See Figure AF003391 Figure 34. Locating Drive Positions (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the plastic retention device. See letter “B” in Figure 36. AF001584 Figure 36. Installing Drive into Drive Carrier (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Note: For proper airflow, you must replace the hard drive carrier in the server system, even if no hard drive is installed in it. 7. When the black lever begins to close by itself, push on it to lock the drive carrier into place. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
4. First time installation only: Remove the knock-out by rocking it back and forth. See letter “A” in Figure 38. You cannot reinstall the knock-out. AF001174 Figure 38. Removing the Knock-out from the Sheet Metal Panel ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Connect the mini SATA power connector on the optical drive. 9. Connect the data cable to the optical drive and to the SATA connector on the server board. AF003257 Figure 40. Installing the Optical Drive into the System ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 41. Removing the Optical Drive from the Server System 7. Remove the four screws that hold the optical drive to the brackets as shown in Figure 42. Save these screws for future use. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
“CD-ROM Assy”. 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
7. Install the screws to lock the drive in place (see letters “B” and “C” in Figure 44). AF001636 Figure 44. Installing the Optical Drive into the System 8. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
5. Remove the optical drive attachment bracket as shown in Figure 46. Figure 46. Removing the Optical Drive from the Attachment Bracket 6. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
5. Lift riser assembly up to remove it. Use caution to gently ease the riser card from the add-in card slot so you do not damage the slot or the riser card. See Figure Riser Socket AF003393 Figure 47. Removing PCIe* Riser Assembly from the Server System ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
The riser cards will seat into the matching sockets on the server board. 4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Card”. 7. Remove the screw that attaches the riser card to the riser assembly. See Figure 49. Save these screws to be used later. AF003288 Figure 49. Removing Riser Card from Riser Assembly ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
10. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. 11. Re-install the processor air duct. For instructions, see “Installing the Processor Air Duct”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Remove the PCIe* Riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 11. Install the server system cover. For instructions, see “Installing the Server System Cover”. 12. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
6. First fit the front of the module into the back panel slot(s), and then attach the module to the server board connector and engage the standoffs (see letter “C” in Figure 53). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
4. Remove the standoffs from the server board (see letter “B” in Figure 54). 5. Install the I/O expansion module filler panel(s) into the system back panel (see letter “C” in Figure 54). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 54. Removing the I/O Expansion Module from the Server System 6. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 7. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Removing the RMM3 Lite 1. Remove the PCI riser assembly. For instructions, see “Removing the PCIe* Riser Assembly”. 2. Disconnect the RMM3 Lite from the server board RMM3 Lite connector (J2D1) as shown in Figure ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 56. Removing the RMM3 Lite to the Server System 3. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCIe* Riser Assembly”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
6. Detach all cables connected to the server board. 7. Remove the heat sink and the processor. For instructions, see “Removing the Heat Sink and Processor”. 8. Remove the DIMMs. For instructions, see “Removing DIMMs”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
15. Install the processor air duct. For instructions, see “Installing the Processor Air Duct”. 16. Install the server system cover. For instructions, see “Installing the Server System Cover”. 17. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
6. Place the server board into the server system as shown by letter “A” in Figure 58. 7. Attach the server board with nine screws. See letter “B” in Figure 58. AF003374 Figure 58. Installing the Server Board ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion. Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. 9. Close the chassis. 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Replacing the Power Supply (SR1630GPRX) Caution: The power supply is NOT hot-swappable. Before removing or replacing the power supply, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
Save this screw. You will re-insert it later. See letter “A” in Figure 61. 6. Remove both the screws and lift up the power supply. See letter "B" in Figure AF003395 Figure 61. Removing Power Supply from the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Set the front of the power supply down by pushing the power supply back. Insert and fasten the three screws you removed in Step 5 and Step 6. AF003396 Figure 62. Installing Power Supply Module into the Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Optical Device HDD 0 HDD 1 AF003376 Figure 63. Connecting Power Cables (SR1630GPRX) 10. Install the server system cover. For instructions, see “Installing the Server System Cover”. 11. Plug all peripheral devices and the AC power cable into the server.
3. Disconnect all power cables connected to the server board and peripherals. 4. Remove both the screws and lift up the power supply. See letter "B" in Figure 64. AF003377 Figure 64. Removing Power Supply from the Server System (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
See letter “A” in Figure 65. 8. Connect the power supply cables to the server board and peripherals. 9. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Replacing the Front Panel Board (SR1630GPRX) Caution: The front panel is NOT hot-swappable. Before removing or replacing the front panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
Figure 67. Installing Front Panel Board into the Server System (SR1630GPRX) 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
6. Slide the front panel board back (see letter “B” in Figure 68) and lift the front panel board from the system (see letter “C” in Figure 68). AF003383 Figure 68. Removing Front Panel Board from the Server System (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
(see letter “B” in Figure 70). 9. Use the screw you removed in Step 5 to attach the front panel board to the system (see letter “C” in Figure 70). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
12. Connect the front panel cable. 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. 14. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
5. Disconnect the two fan cables from the server board (see letter “B” in Figure 72) and untie the cable tie (see letter “C” in Figure 72). AF003275 Figure 72. Disconnecting System Blower Fans (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Lift the fan bracket from the server. Lift the bracket at an angle, front of the bracket first, to clear the hard disk drive brackets. See letter “C” in Figure 73. AF003276 Figure 73. Removing Bracket and System Blower Fans from Server System (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 74. 10. Lift the fan from the bracket. See letter “B” in Figure 74. AF000963 Figure 74. Removing Fan from Fan Bracket (SR1630GPRX) 11. Install the replacement fan onto the bracket, using the two screws you removed in Step 9.
14. Connect the fans to the server board. See letters “A” and “B” in Figure 75. AF003277 Figure 75. Connecting System Blower Fans (SR1630GPRX) 15. Install the processor air duct. For instructions. see “Installing the Processor Air Duct”. ® Intel...
5. Remove the two screws that hold the fan in place. Save these screws. You will re- install them later. 6. Disconnect the fan cable from the server board (see letter “B” in Figure 76). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
8. Install the replacement fan into the chassis (see letter “A” in Figure 77), using the two screws you removed previously. 9. Connect the fan cable to the server board (see letter “B” in Figure 77). 10. Install the processor air duct (see letter “C” in Figure 77). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Information”. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Attach the rack handle to the server system with two screws as shown in Figure 78. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
AF001204 Figure 78. Installing the Rack Handle 4. Repeat Step 3 on the opposite side of the server. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Figure 79. AF001204 Figure 79. Removing the Rack Handle 4. Repeat Step 4 on the opposite side of the system. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
For example, the PCI cooling fan cable is labeled with the letter “C” both where it connects to the server board and at the PCI cooling fan itself. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
SATA-0 Front Panel location. System Fan Blower Power ... left fan System Fan Blower Power ... right fan Power to Server Board (Main) AF003389 Figure 80. Data Cable Routing (SR1630GPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Link to backplane SPGIO Optical Drive to Power Supply Sys fan Power PSU management bus to AUX Server Board SATA Connector Legend Begin cable connections at the SATA-0 location. AF003390 Figure 81. Cable Routing (SR1630HGPRX) ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
“Calculating Power Usage”. Table 7. Power Supply Output Capability Voltage Maximum Current +3.3 V 6.8 A +5.0 V 10.9 A +5 V Standby 1.9 A +12.0 10.8 A -12.0 V 0.4 A ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
7 Bels in sound power for a typical office ambient temperature (65 to 75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 8 Kilovotls (KV) contact discharge, 12 kilovolts (KV) air discharge; discharge (ESD) no component damage. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 122
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
See “Server System References” for links to the tested component lists. Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
• Characters on the screen appear distorted or incorrect. • System cooling fans do not rotate. • Diskette drive activity light does not light. • Hard disk drive activity light does not light. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Are the brightness and contrast controls on the video monitor properly adjusted? • Is the video monitor signal cable properly installed? • Does this video monitor work correctly if plugged into a different system? ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
If the system cooling fans are not operating properly, it is an indication of possible system component failure. Check the following: • Is the power-on light lit? If not, see “Power Light Does Not Light”. • Are any other front panel LEDs lit? ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Make sure the driver is loaded and the protocols are bound. • Make sure the hub port is configured for the same duplex mode as the network controller. • Make sure the correct networking software is installed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Before installing a PCI card, you should always: • Turn off the server power by using the power button on the front of the system. • Unplug the AC power cord(s) from the server. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Devices are not Recognized under Device Manager (Microsoft Windows* Operating System) ® The Microsoft Windows* operating systems do not include all of the drivers for the Intel chipsets, onboard NICs, and other components. See “Server System References” for a link to the current drivers and chipset files.
BIOS beep codes. Table 11. POST Error Beep Codes Number of Reason for Beeps and Action to Take Beeps System halted because a fatal error related to the memory was detected. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 134
Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Dispose of used batteries according to manufacturer's instructions. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Netzgerät ein eigenes Netzkabel. Der Wechselstrom des Systems wird durch den Ein-/Aus-Schalter für Gleichstrom nicht ausgeschaltet. Ziehen Sie jedes Wechselstrom-Netzkabel aus der Steckdose bzw. dem Netzgerät, um den Stromanschluß des Systems zu unterbrechen. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 136
4. Bringen Sie die Verschlußeinrichtung (Padlock) wieder an und schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. 5. Schließen Sie alle externen Kabel und den AC Stromanschlußstecker Ihres Systems wieder an. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Français Le bloc d'alimentation de ce produit ne contient aucune pièce pouvant être réparée par l'utilisateur. Ce produit peut contenir plus d'un bloc d'alimentation. Veuillez contacter un technicien qualifié en cas de problème. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 138
Procédez comme suit: 1. Si un cadenas a été installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 139
• "Muni d'une prise murale correctement mise à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
- o a cualquier tipo de superficie de metal sin pintar. 6. No ponga en marcha el sistema si se han extraído las tapas del chasis. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 141
Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 142
• "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 144
• "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored. Indicates potential hazard if indicated information is ignored. Indicates shock hazards that result in serious injury or death if safety instructions are not followed. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. Equipment Handling Practices Reduce the risk of personal injury or equipment damage: ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Disconnect all cables and telecommunication lines that are connected to the compute module. • Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Komponenten, die im vorliegenden Handbuch angegeben werden. Die Verwendung anderer Produkte oder Komponenten führt zum Erlöschen der UL-Zulassung und anderer Genehmigungen für das Produkt. Dadurch kann das Produkt gegen Produktbestimmungen verstoßen, die im Verkaufsland gelten. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder Prüfgeräte) kann u. U. weitere Tests erfordern. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage.Verwenden Sie dazu, sofern verfügbar, eine leitfahige Schaumstoffunterlage, aber niche die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
• Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Français Consignes de sécurité sur le serveur ® ® Ce document s’applique aux cartes serveur Intel , au châssis de serveur (sur pieds et Intel sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre...
Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel. • Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en marche que lorsque les panneaux du châssis sont en place. L’utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux : ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor ® Este documento se aplica a las tarjetas de servidor de Intel , los gabinetes de servidor de ® Intel (montaje en rack y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y...
Es posible que sea necesario llevar a cabo una evaluación adicional para comprobar si este producto es apropiado para otras categorías de productos y entornos además de las aplicaciones informáticas (por ejemplo, soluciones médicas, industriales, residenciales, sistemas de alarma y equipos de pruebas). ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
CA estén desenchufado antes de abrir le gabinete, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques eléctricos use precauciones al ®...
A no ser que esté instalando o extrayendo un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Para instalar las cubiertas: • Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema. • Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 165
Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 166
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 167
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
(or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
This server system has been tested and verified to comply with the following ® electromagnetic compatibility (EMC) regulations when installed in a compatible Intel host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. ®...
Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
Page 176
— CE DOC (Europe) — CB Certificate & Report (International) Note: CB to include all CB national deviations) Certification marks to be visible on power supply. Power supply to comply with the Intel power supply specification. • Peripheral Devices (e.g. Disk Drives, CD ROMs) —...
GOST R Certification / License (Russia) • KCC Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Ctick Mark Australia / NZ N232 CANADA ICES-003 CLASS A EMC Marking Canada CE Mark Europe GS Mark Germany VCCI Mark Japan KCC Mark Korea 인증번호 : CPU-SR1630 (A) GOST Mark Russia ME06 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 179
“Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.” Finnish on line 3: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.” English on line 4: “Connect only to a properly earth grounded outlet.” ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 180
Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung. WEEE WEEE Marking Marking China RoHS China RoHS China Recycling Package China Recycling Marks Package Marks Will be added on Package label. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 181
Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. Standard icon for Power button Should be attached on power button ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4.
"as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
Page 188
® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). ® Before calling, fill out an Intel Server Issue Report Form.
Page 190
Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Page 191
Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1630GPRX/SR1630HGPRX Service Guide...
Need help?
Do you have a question about the SR1630GPRX and is the answer not in the manual?
Questions and answers