6.7.5
Conversion Rate Register
The contents of the conversion rate register determine the nominal rate at which
analog-to-digital conversions happen when the thermal sensing device is in auto-
convert mode.
and the conversion rate. As indicated in
to its default state of 02h (0.25 Hz nominally) when the thermal sensing device is
powered-up. There is a ±25% error tolerance between the conversion rate indicated in
the conversion rate register and the actual conversion rate.
Table 6-16. Thermal Sensing Device Conversion Rate Register
Register Contents
90
Table 6-16
shows the mapping between conversion rate register values
Conversion Rate (Hz)
00h
01h
02h
03h
04h
05h
06h
07h
08h to FFh
Reserved for future use
Dual-Core Intel
System Management Feature Specifications
Table
6-16, the conversion rate register is set
0.0625
0.125
0.25
0.5
1
2
4
8
§
®
®
Itanium
Processor 9000 and 9100 Series Datasheet