NEC PowerMate Pro150 Series Service Manual page 112

Hide thumbs Also See for PowerMate Pro150 Series:
Table of Contents

Advertisement

Problem
Symptom
Operating system
Intermittent beeping at
does not boot
power-on. Computer beeps
more than once and is unable
to complete boot-up.
"Invalid Configuration"
message displayed.
Computer halts during
loading sequence.
Diskette drive does
Lamp on drive panel does not
not work
light when diskette is loaded.
Hard disk
Hard disk drive lamp does not
malfunction
light but hard disk drive can
be accessed.
Hard disk controller failure
message displayed.
Table 4-4 Problems and Solutions
Maintenance and Troubleshooting
Solution
1. Check system configuration and switch
settings (refer to Appendix B).
2. Verify that drives are enabled.
3. Reseat SIMMs and option boards in
their connectors. Inspect system board for
dropped objects.
4. Remove option boards and reboot.
5. Replace system board.
1. Press F1 to run Setup and correct the
parameters.
2. Replace the CMOS battery if the date
and time must be set each time the
computer is powered on.
1. Power the computer off. Check for
proper jumper settings (see Section 2),
then power-on the computer.
2. Check condition of selected bootload
device (diskette or hard disk) for bad boot
track or incorrect OS files.
3. Try booting OS from diskette or recopy
OS files onto hard disk.
4. Verify correct hard disk is selected.
1. Check power and signal cable
connections between diskette drive,
system board, and power supply.
2. Check diskette drive jumpers.
3. Check power supply and replace
diskette cable.
4. Replace diskette drive.
5. Replace system board.
1. Check cable connections between
lamp and system board.
1. Check that the IDE port and hard disk
drives are enabled in Setup.
4-9