Channel No.: Select the channel number of the corresponding card where the COM port
is located.
Baud Rate, Data Bits, Stop Bits and Parity: Set the communication parameters
between the COM port and the controlled device. Please refer to the relevant
parameters of the controlled device for configuration.
Step 3 Rotate the knob to select Apply and press the knob to confirm.
2.2.4.2
I/O Settings
Step 1 On the main menu screen, rotate the knob to select Advanced Settings and press the knob
to enter the advanced settings screen.
Step 2 On the advanced settings screen, rotate the knob to select I/O Settings and press the knob
to enter the I/O settings screen.
Figure 2-8 I/O settings
Slot No.: Select the slot number of the corresponding card where the I/O port is located.
CTRL: Main control card
Channel No.: Select the channel number of the corresponding card where the I/O port is
located.
Mode: The supported modes include Input, Output-High, Output-Low. Select one of
the modes according to the connected device.
When the I/O connector is connected to the device for signal input, such as smoke
−
sensors, and temperature and humidity sensors, you need to set the I/O mode to
Input.
When the controlled device is connected and the I/O connector is used for control,
−
you need to set the mode to Output-High or Output-Low according to the signal
received by the controlled device.
Step 3 Press the ESC to exit the current menu and apply the configuration.
www.novastar.tech
Vunit 3000 Professional Control Processor User Manual
7