Cross-Sectional Area - Omron ZG User Manual

2d profile measuring sensors
Hide thumbs Also See for ZG:
Table of Contents

Advertisement

< Cross-sectional area >
The cross-sectional area of the profile inside the region is measured.
Measurement of the cross-sectional area is enabled only in the EXP mode.
Icon
Area
Illustration of setting
Set the area for the cross section.
Cross section
How to adjust the region p.66
< Calculation >
The measurement results of other tasks can be used for calculation.
The calculation setting is enabled only in the EXP mode.
Icon
Calc
< Deleting measurement items >
Icon
Delete
ZG User's Manual
Description
Cross-sectional
area (mm
Description
Set any equation to perform addition/subtraction on the
measurement result. The equation can be substituted with
measurement results obtained by other tasks.
Allowable equation: K+mX+nY
• K range:
-999.99999 to 999.99999
(default value: 0.00000)
• m/n range:-10.0 to 10.0 (default value: 1.0)
• X/Y range:OFF (default value: OFF), TASK1 to TASK7 (Only
task Nos. smaller than the task No. to which a
calculation is set can be set.)
Description
Delete the measurement items that are set to the currently selected
task.
The cross-sectional area of the
object can be measured. Specify
2
)
the bottom face. The cross-
sectional area is calculated by
integrating the distances between
each of the measurement points
and the bottom face.
Measurement Settings
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zg seriesZg-wds70Zg-wds22Zg-wds8tZg-wds3t

Table of Contents