Command Processing Time - Omron ZG User Manual

2d profile measuring sensors
Hide thumbs Also See for ZG:
Table of Contents

Advertisement

Command Processing Time

The command processing time differs according to the command.
The following shows typical command processing times for the TRIG, MEASURE and
PROFILE commands.
Command
TRIG
MEASURE
PROFILE 0
(profile output format: ASCII)
PROFILE 1
(profile output format: binary)
The command processing time above shows measurement values for the ECO monitor.
ZG User's Manual
Setting
Sensitivity: MULTI, CCD mode: NORMAL
Sensitivity: MULTI, CCD mode: HI-RESO
Sensitivity: MULTI, CCD mode: HI-SPEED 170 ms
Sensitivity: FIXED, CCD mode: NORMAL
Sensitivity: FIXED, CCD mode: HI-RESO
Sensitivity: FIXED, CCD mode: HI-SPEED 10 ms
-
-
-
Processing time
RS-232C
USB
(115200 bps)
280 ms
280 ms
550 ms
550 ms
170 ms
20 ms
20 ms
30 ms
30 ms
10 ms
10 ms
10 ms
1500 ms
1000 ms
250 ms