Setting Smoothing
The intermediate value of past measurement results can be output as the measurement
value. This function removes any abnormal values, such as spiking, that occur when the
shape of the measurement target suddenly changes during measurement.
ADJ mode-MENU/VIEW key-[FILTER]-[SMOOTH]
Setting value
OFF, LOW, MID, HIGH
Important
Smoothing is invalid when the measurement trigger and sensitivity adjustment settings are
combined as follows. (Smoothing is not executed even if it is set.)
• Trigger enabled + multiple sensitivity
• Trigger enabled + fixed sensitivity
Setting Processing during Non-measurement
Set the output methods for when a non-measurement state occurs temporarily, for
example, due to insufficient received light amount or the reset input status.
ADJ mode-MENU/VIEW key-[ERROR]-[ERROR]
Setting value
KEEP
CLAMP
Note
When [CLAMP] is selected, set the clamp value to be output.
Analog output p.94
ZG User's Manual
Description
Sets the smoothing strength. (default value: LOW)
The intermediate value of the past measurement values for the
preset filter value at each individual
the measurement result.
LOW: 3 times, MID: 9 times, HIGH: 15 times
Description
The status immediately before measurement is stopped is held and
output.
The preset clamp value (abnormal value) is output. (default value)
Checking/Adjusting the Measurement Status - ADJ Mode
measurement
cycle is set as
53