Parameters during setting of measurement conditions
Region P
Parameter
P1 start
P1 end
P2 start
P2 end
P3 start
P3 end
Measurement point selection
Parameter
P1
P2
P3
Edge selection
Parameter
P1 edge level
P2 edge level
P1 edge direction
P2 edge direction
150
Serial Communication
Unit No.
Parameter No.
47+10 * (task-1)
4
47+10 * (task-1)
5
47+10 * (task-1)
11
47+10 * (task-1)
12
47+10 * (task-1)
18
47+10 * (task-1)
19
Unit No.
Parameter No.
47+10 * (task-1)
6
47+10 * (task-1)
13
47+10 * (task-1)
20
Unit No.
Parameter No.
47+10 * (task-1)
7
47+10 * (task-1)
14
47+10 * (task-1)
10
47+10 * (task-1)
17
Setting range
0 to 630
0 to 630
0 to 630
0 to 630
0 to 630
0 to 630
Setting range
0: Average, 1: Peak, 2: Bottom
0: Average, 1: Peak, 2: Bottom
0: Average, 1: Peak, 2: Bottom
Setting range
High-speed mode: 0 to 199
Standard, high-resolution mode:
0 to 399
High-speed mode: 0 to 199
Standard, high-resolution mode:
0 to 399
0: left → right (forward direction)
1: right → left (reverse direction)
0: left → right (forward direction)
1: right → left (reverse direction)