Entp Trap: Enab
Next
Enab
Disab
Prev
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled.
Enab – Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).
Disab – Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the
Options
section on page C-15) is disabled.
Link Trap: Both
Next
Disab
Up
Down
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown traps are specified
with the Trap I/F configuration option.
Disab – Disables the sending of trap messages for linkDown or linkUp events.
Up – Sends trap messages for linkUp events to the currently configured trap manager(s).
Down – Sends trap messages for linkDown events to the currently configured trap manager(s).
Both – Sends trap messages for linkUp and linkDown events to the currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the
Options
section on page C-15) is disabled.
Trap I/F: Both
Next
NET
DTE
Both
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap messages. These traps are supported
on the T1 interfaces (network and DTE).
NET – Sends trap messages for linkUp and linkDown events occurring on the network interface.
DTE – Sends trap messages for linkUp and linkDown events occurring on the DTE interface.
Both – Sends trap messages for linkUp and linkDown events occurring on both the network and DTE interface.
NOTE: This configuration option is not available if the Link Trap configuration option is not configured to generate trap
messages for linkUp or linkDown events.
3150-A2-GB21-80
Table C-7
(2 of 2)
Management Trap Configuration Options