Paradyne 3150 Operator's Manual page 115

Acculink 315x channel service unit
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

ACCULINK 315x CSU
propPointToPointSerial(22) – Used for the
MODEM or COM port when the port is not
configured as the SNMP management interface.
ppp(23) – Used for the MODEM, AUX, or COM
port when the port is configured for PPP.
slip(28) – Used for the MODEM or COM port
when the port is configured for SLIP.
Interface Group – "ifMtu" Object (ifEntry 4)
This object identifies the largest datagram that can be
sent or received on the interface. It is applicable only to
the interface configured as the SNMP management link.
This object is zero for all other interfaces.
Interface Group – "ifSpeed" Object (ifEntry 5)
This object provides the interface's current bandwidth
in bits per second. The value of this object for each
interface is specified as follows:
T1 Interfaces:
1,544,000 bps.
COM, AUX,
The currently configured data rate
and MODEM:
for the port.
Interface Group – "ifAdminStatus" Object
(ifEntry 7)
This object specifies the desired state (configuration)
of the interface. This object is supported only for the
COM and MODEM ports. It provides the ability to switch
between using the port for SNMP or ASCII operations
(dial-out, front panel emulation). The value of this object
will not affect the state of any of the interfaces on the
CSU other than the COM or MODEM port. Only the
following values are supported by the CSU:
up(1) – The SNMP management link is active on
the COM or MODEM ports.
testing(3) – The SNMP management link is inactive
on the COM or MODEM ports. These ports can be
used for proprietary ASCII functions.
E-4
Interface Group – "ifOperStatus" Object
(ifEntry 8)
This object specifies the current operational state of the
interface. The value of this object for each interface is
defined as follows:
Network T1:
DTE T1:
COM Port:
AUX Port:
MODEM Port:
February 1998
The interface is up(1) when no
alarm conditions exist.
The interface is down(2) when an
alarm condition is active.
The interface is testing(3) when a
test is active on the interface.
The interface is up(1) when no
alarm conditions exist and the
interface is enabled.
The interface is down(2) when an
alarm condition is active and the
interface is disabled.
The interface is testing(3) when a
test is active on the interface.
When configured as an SNMP
management link, up and down are
based on the current state of the
link layer protocol. Otherwise, the
interface is always up(1).
The interface is never in the
testing(3) state.
When configured as an SNMP
management link, up and down are
based on the current state of the
link layer protocol. Otherwise, the
interface is always down(2).
The interface is never in the
testing(3) state.
When configured as an SNMP
management link, up and down are
based on the current state of the
link layer protocol. Otherwise, the
interface is always up(1) when the
modem is connected and down(2)
when the modem is not connected.
The interface is never in the
testing(3) state.
3150-A2-GB21-80