ACCULINK 315x CSU
To clear the performance registers,
1. From the top-level menu screen, press the
until the Ctrl selection appears on the screen.
2. Select Ctrl.
3. From the Control screen, select ClrReg.
Control:
Call
F1
Register
Event
ESF error events counter. An error event is an
ESF frame with either a Cyclic Redundancy
Check (CRC) error or an Out Of Frame (OOF)
event. The maximum count is 65,535. This
register is only reset as a result of a reset
command from the network. This register is
valid for the current interval only.
CurTimer
Current interval timer. This register records the
number of seconds in the current 15-minute
interval. The maximum is 900 seconds. This
register is valid for the current interval only.
VldIntvl
N/A
ES
The number of errored seconds for the current
interval. An errored second is any second with
one or more ESF error events. The maximum is
900 seconds.
UAS
The number of unavailable seconds for the
current interval. An unavailable second is any
one second interval when service is
unavailable. (Detection occurs with
10 consecutive unavailable seconds.) The
maximum is 900 seconds.
SES
The number of severely errored seconds for the
current interval. A severely errored second is
any second with 320 or more CRC errors, or
any second with one or more OOF events. The
maximum is 900 seconds.
4-6
key
Rel
ClrReg
F3
F2
Table 4-3
Performance Registers
Interval Description
February 1998
4. From the Clear Prf Regs screen, press F1 to clear
the User registers.
If you selected User, the User performance
registers are cleared, all accumulators are reset to
zero, and all status registers are cleared. The
current interval timer, the number of valid
intervals count, and the total 24-hour counts are
reset to zero. The Command Complete message
then appears.
(1 of 2)
N/A
N/A
Valid interval total. Records the number of valid
15-minute intervals in the previous 24 hours. This
register is not valid for the current interval.
The total number of errored seconds for the previous
24 hours.
The total number of unavailable seconds for the
previous 24 hours.
The total number of severely errored seconds for the
previous 24 hours.
Clear Prf Regs:
User
F3
F1
F2
Totals Description
3150-A2-GB21-80