ACCULINK 315x CSU

Test Commands

The test commands enable you to run loopbacks and
test patterns on the CSU, and to test the front panel LEDs.
These tests can help you isolate areas of trouble if you are
having problems with your CSU.
To access all Test commands from the Test branch,
press F2 to select Test from the top-level menu screen.
CSU ESF
Stat
Test
F1
F2

Remote Loopback Tests

The Remote Loopback tests enable you to troubleshoot
your circuit by sending the following to a far-end device:
Line loopback up activation sequence for
10 seconds (LLBUP)
Line loopback down activation sequence for
10 seconds (LLBDN)
You cannot perform remote loopbacks if any of the
local loopbacks are active. If you attempt to do so, the
error message Invld Test Combo (Invalid Test
Combination) appears.
NOTE
The following procedures are
examples only. Screen displays
may vary depending on the
model and configuration of the
CSU.
4-14
Cnfig
F3
February 1998
To send a Line Loopback Up or Down sequence on the
network to a far-end CSU,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Rlpbk.
Test:
Rlpbk Lpbk
F1
3. From the Rem Loopback screen, press F1 to select
LLBUP (Line Loopback Up), or press F2 to select
LLBDN (Line Loopback Down).
Rem Loopback:
LLBUP LLBDN
F1
The Line Loopback sequence is sent up or
downstream to the far-end CSU for 10 seconds.
During this time, Sending appears on Line 2 of
the LCD, followed by Command Complete when
10 seconds have elapsed.
You can press any function key to restore the Rem
Loopback screen without affecting transmission of
the loopback code.
Ptrns
F2
F3
F2
F3
3150-A2-GB21-80