ACCULINK 315x CSU

Self-Test Health

Use the Self-Test Health command to display the
results of the power-up self-test. Possible messages are
listed in
Table
4-1. See Chapter 2, Installation, for more
information about power-up self-test.
To display power-up self-test results,
1. From the top-level menu screen, select Stat.
CSU ESF
Stat
F1
Message
Passed
No problems were found during power-up.
CPU fail
The central processing unit failed internal testing.
Device fail
One or more of the unit's integrated circuit chips failed to pass internal device level testing.
B8ZS/LOS fail
The unit failed to encode data properly or to detect Loss Of Signal.
Alarm fail
The unit failed to transmit AIS or to detect an Yellow alarm.
Memory fail
The unit failed program checksum verification.
LCD fail
The front panel liquid crystal display (LCD) failed.
NET T1 fail
The unit failed to internally loop data on the network T1 circuit.
DTE T1 fail
The unit failed to internally loop data on the DTE T1 circuit.
Modem fail
Unit failed to internally loop data through the modem circuit.
Failure xxxxxxxx
An 8-digit hexadecimal failure code is provided for service personnel.
4-2
Test
Cnfig
F3
F2
Self-Test Health Messages
February 1998
2. From the Status screen, select STest.
3. View the results of the last power-up self-test. If
no problems were found during power-up, the
following message appears.
Table 4-1
Description
Status:
DevHS STest
Perf
F3
F1
F2
STest Health:
Passed
F1
F2
F3
3150-A2-GB21-80