Near End Group – "dsx1CircuitIdentifier" Object
(dsx1ConfigEntry 8)
This object is only supported on the Net T1 Interface.
Near End Group – "dsx1LoopbackConfig"
Object (dsx1ConfigEntry 9)
This object specifies the loopback state of the T1
interfaces. Only the following values are supported by the
CSU.
dsx1NoLoop(1) – The T1 interface is not in a
loopback state.
dsx1PayloadLoop(2) – Specifies that a Payload
Loopback (PLB) is active for the network interface
or a Repeater Loopback (RLB) is active for the
DTE interface.
dsx1LineLoop(3) – Specifies that a Line Loopback
(LLB) is active for the network interface or a DTE
Loopback (DLB) is active for the DTE interface.
Near End Group – "dsx1LineStatus" Object
(dsx1ConfigEntry 10)
This object specifies the line (alarm) status of the T1
interfaces. Only the following values are supported by the
CSU. More than one value may be active at a time.
dsx1NoAlarm(1) – No alarm present.
dsx1RcvFarEndLOF(2) – A yellow alarm signal is
being received.
dsx1RcvAIS(8) – An Alarm Indication Signal
(AIS) is being received.
dsx1LossOfFrame(32) – An Out Of Frame
condition has persisted for more that 2.5 seconds
(i.e., Red Alarm).
dsx1LossOfSignal(64) – A Loss of Signal condition
has persisted for more that 2.5 seconds (i.e., Red
Alarm).
dsx1LoopbackState(128) – The near end of the T1
interface is in a loopback state.
dsx1Other Failure(4096) – An Excessive Error Rate
(EER) has been detected on the network interface.
3150-A2-GB21-80
Near End Group – "dsx1SignalMode" Object
(dsx1ConfigEntry 11)
This object specifies whether Robbed Bit Signaling
(RBS) is being used. This object differs from the MIB
definition in that it is "read-only" (not read/write) for
CSUs. Only the following values are supported by the
CSU.
none(1) – No signaling is being used on this
interface.
robbedBit(2) – Robbed Bit Signaling is being used
on at least one DS0 on this T1 interface.
Near End Group – "dsx1TransmitClockSource"
Object (dsx1ConfigEntry 12)
This object specifies the timing source for the transmit
clock for this T1 interface. This object differs from the
MIB definition in that it is "read-only" (not read/write) for
CSUs. Only the following values are supported by the
CSU.
loopTiming(1) – The recovered receive clock is
being used as the transmit clock.
localTiming(2) – The CSU's internal clock is being
used as the transmit clock.
ThroughTiming(3) – The recovered receive clock
from another interface (e.g., T1, Port, or External)
is being used as the transmit clock.
Near End Group – "dsx1Fdl" Object
(dsx1ConfigEntry 13)
This object specifies how Facility Data Link is being
used. Only the following values are supported by the
CSU. More than one value may be active at a time.
dsx1other(1) – SNMP data is being sent over FDL.
dsx1Ansi-T1-403(2) – ANSI PRMs are supported
on the network interface as specified by
ANSI T1.403.
dsx1Att-54016(4) – FDL supports the requirements
specified by AT&T publication TR54016.
dsx1Fdl-none(8) – Indicates that the device does
not use FDL. This is the only value that applies to
the DTE interface.