BES
The number of bursty errored seconds for the
current interval. A bursty errored second is any
second with more than one, but less than 320,
CRC errors. The maximum is 900 seconds.
LOFC
The loss of frame count for the current interval.
This is a count of the number of times that an
LOF is declared. The maximum count is 255.
StEvnt
The status events register records whether one
(Only valid for
or more of the following events have occurred
User registers.)
at least once during the interval. The event is
identified by a letter as follows:
Y – A Yellow Alarm signal has been received
on the network interface.
L – Loss Of Signal has occurred on the DTE
interface.
E – The Excessive Error Rate threshold has
been exceeded.
F – A Frame Synchronization Bit Error has
been detected.
V – A Bipolar Violation has been detected.
If none of these events occurred during the
interval, StEvnt=none will be displayed.
3150-A2-GB21-80
Table 4-3
(2 of 2)
Performance Registers
Interval Description
February 1998
Totals Description
The total number of bursty errored seconds for the
previous 24 hours.
The total loss of frame count for the previous
24 hours.
N/A
Maintenance