Paradyne 3150 Operator's Manual page 98

Acculink 315x channel service unit
Hide thumbs Also See for 3150:
Table of Contents

Advertisement

ACCULINK 315x CSU
Num Trap Mgrs: 1
Next
1
2
3
4
5
Number of Trap Managers. Specifies the number of SNMP trap managers that are to receive traps for this unit.
NOTE: You must configure an IP address for each trap manager that is to receive trap messages.
Trap n IP Adr:
Next
Edit
Clear
Prev
Trap n IP Address. Specifies the IP address for each trap manager. This configuration option is repeated for all trap
managers supported by the unit.
Edit – Allows you to edit or display the IP address for Trap Manager n .
Clear – Allows you to clear the IP address for Trap Manager n . The IP address is set to 000.000.000.000.
Trap n Dst: None
Next
None
IPBus
Trap Manager n Destination. Specifies the network destination for Trap Manager n . This configuration option is displayed
for the number of trap managers ( n ) specified by the Number of Trap Managers configuration option.
None – No Trap Manage n network destination. Traps are discarded.
IPBus – The Trap Manager n network destination is the IP Bus on the carrier backplane. This selection only appears for
carrier-mounted CSUs which are not configured as the IP Bus Master.
Com – The Trap Manager n network destination is the communication port. This selection only appears if the Com Use
configuration option is set to Mgmt or Daisy.
Modem – The Trap Manager n network destination is the modem port. This selection only appears if the Modem Use
configuration option is set to Mgmt. This selection does not appear on carrier-mounted CSUs.
Aux – The Trap Manager n network destination is the auxiliary port. This selection only appears if the Aux Use
configuration option is set to Mgmt or Daisy.
FDL – The Trap Manager n network destination is the FDL management link. This selection only appears if the FDL
management link is enabled.
NOTE: If the chosen destination link is disabled or down, the traps are discarded. Return to this menu and choose
another destination.
Gen Trap: Both
Next
Disab
Warm
General Trap Types. Specifies the general trap types to enable.
Disab – Disables the sending of trap messages for warmStart and authenticationFailure events.
Warm – Sends trap messages for warmStart events to the currently configured trap manager(s).
Auth – Sends trap messages for authenticationFailure events to the currently configured trap manager(s).
Both – Sends trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the
Options
section on page C-15) is disabled.
C-24
Management Trap Configuration Options
6
Prev
Com
Modem
Aux
FDL
Auth
Both
Prev
Table C-7
(1 of 2)
Prev
February 1998
Alarm Configuration
3150-A2-GB21-80