Alarm Configuration Options
Alrm Msg: Disab
Next
Disab
Modem
Alarm Messages. Controls the generation of alarm messages, which are routed to an ASCII terminal or printer attached to
the communication port and/or the modem port.
Disab – Prevents an alarm message for any alarm conditions.
Modem – Enables alarm messages routed to the modem port. This selection does not appear on carrier-mounted CSUs.
Com – Enables alarm messages routed to the communication port.
Both – Enables alarm messages routed to both the modem and communication ports. This selection does not appear on
carrier-mounted CSUs.
NOTE: Alarm messages are only sent to the communication port if the Com Use configuration option is set to ASCII,
otherwise the alarm messages are discarded.
SNMP Trap: Disab
Next
Enab
Disab
Prev
SNMP Trap Enable. Specifies whether SNMP trap messages are sent over the SNMP management link.
Enab – Enables sending SNMP trap messages from this unit over any SNMP management link.
Disab – Disables sending SNMP trap messages from this unit over any SNMP management link.
NOTE: For carrier-mounted CSUs that have the communication port enabled, the only traps that are disabled are those
that pertain to this particular unit. Traps from other units are passed through.
Trap Disc: Enab
Next
Enab
Disab
Prev
SNMP Trap Disconnect. Specifies whether the modem connection or carrier external communication port device
connection is disconnected after sending a trap message. This configuration option applies only to modem connections or
carrier external communication port device connections initiated as a result of the trap message being sent.
Enab – Specifies that the modem call or carrier external communication port device call is disconnected after a trap
message is sent.
Disab – Specifies that the modem call or carrier external communication port device call is not disconnected after a trap
message is sent. The line is held until it is manually disconnected or disconnected by the remote modem.
NOTE: This configuration option is only available if SNMP traps are enabled and the integral modem or the carrier
external communication port device is enabled and configured as an SNMP management link.
3150-A2-GB21-80
Table C-5
Alarm Configuration Options
Com
Both
Prev
February 1998
A triangular symbol ( ) identifies
a configuration option that is
available on carrier-mounted
CSUs only.
(1 of 3)
Configuration Options
NOTE
C-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

3151

Table of Contents