Electrical Connection (1*0Bm2E) - Angelo Po 0N0BM1E User Manual

Electric bain-marie
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
WARNING: The connection must be
made by authorised, skilled personnel, in
accordance with the relevant legal require-
ments, using appropriate and specifi ed ma-
terials.
The appliance is supplied with operating
voltage 400V3~N , which can be switched to
230V3.
Direct connection to the mains requires a de-
vice ensuring disconnection from the mains,
with a contact opening distance that allows for
complete disconnection under the conditions
of overvoltage category III, in compliance with
the installation rules.
HAZARD: Before doing any work, turn
off the general power supply.
Connect the appliance to the mains electricity
supply as follows:
If not already in place, install an automatic
1)
switch-disconnector (A) close to the appli-
ance, with the following characteristics:
– Thermal release (see table in the Annex sec-
tion for adjustment instructions).
12

ELECTRICAL CONNECTION (1*0BM2E)

A
B
C
D
– Reed switch curve B (IEC 60898-1).
– Residual current release set at 30 mA
Pull off the knob (B).
2)
Take out the screws (C)and take down the
3)
dashboard (D).
Connect the circuit-breaker (A) to the termi-
4)
nal board (F) as shown in the diagram and in
the electrical system diagram at the back of
the manual and using a cable with the fol-
lowing:
– Weight: ≥ than H05RN-F type (designation
245 IEC 57).
– Temperature of use: ≥ 70°C.
WARNING: When connecting, pay at-
tention to the neutral and earth cable con-
nection.
Tighten the cable gland (F).
5)
Replace all when the operation is complete.
6)
E
C
HANDLING AND INSTALLATION
F
3319950_inst_GB_rev.3

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

0t0bm1e1n0bm2e1t0bm2e

Table of Contents