Register Address Data - Watkins-Johnson Company WJ-8718A/MFP Instruction Supplement

Microprocessor front panel option
Hide thumbs Also See for WJ-8718A/MFP:
Table of Contents

Advertisement

WJ-8718A/MFP
Table 2-19. Register Address Data
TABLE 2-19
Register
Data Word
2 7
?6
2
5
2
4
2
3
22
2
1
2
0
....
,..:..I~.
0
0
0
0
2
3
22
2
1
2
0
0
NOT USED
10
1
BFO FREQ
0
0
G2
G1
2 1
10
2
1
R/L
NOT
+/-
GAIN
10 7 TUNED
USED
BFO
MODE
FREQ
2 3
2
2
2
1
2
U
2;)
2:::
2
1
1
U
2
10 6 TUNED FREQ
10
5
TUNED FREQ
2
3
22
2
1
2
0
2
3
22
2
1
1
0
3
10
4
TUNED FREQ
10
3
TUNED FREQ
2
3
22
2
1
2
0
2
3
22
2
1
1
0
4
10
2
TUNED FREQ
10
1
TUNED FREQ
B3
B2
Bl
D5
D4
D3
D2
Dl
5
BANDWIDTH
DETECTION MODE
2
3
2
2
2
1
2
0
2
3
2
2
2
1
1
0
6
10
3
BFO FREQ
10
2
BFO FREQ
R/O
R/S
R/S
R/S
R/S
R/S
R/S
R/S
7
*
MONITOR = SIGNAL STRENGTH(S)
COMMAND = RF GAIN (R)
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
COR X
X
X
COR THRESHOLD
FLG
* Bit is unused in MONITOR Mode: must be 0
NOTE:
BFO and TUNED frequencies in BCD (Hz)
Function Codes
R/L:
1 = Remote, 0 = Local
GAIN MODE
G2
Gl
FAST AGC
=
0
0
+/- BFO: 1
=
-j
0 = +
MANUAL
=
0
1
SLOW AGC
=
1
0
Bandwidth (in kHz)
B3 B2 B1
DET MODE
D5
D4
D3
D2
D1
16
=
0
0
0
AM
=
1
1
1
0
1
6
=
0
0
1
FM
=
1
1
1
0
0
3.2
=
0
1
0
CW
=
0
1
0
1
1
1
=
0
1
1
ISB*
=
0
0
0
1
0
.3
=
1
0
0
USB*
=
0
0
0
0
1
LSB*
-
0
0
0
0
0
* :
SSB selected BFO Tuninpo Disabled
RF Gain (Command)
Signal Strength (Monitor)
Max (0)
0
0
0
0
0
0
0
0
No Signal (0)
0
0
0
0
0
0
0
Min (255)
1
1
1
1
1
1
1
1
Max (128)
1
1
1
1
1
1
1
2-27