Access Tier 2 Format; Full Status Command; Command Bfo Frequency; Tier 2 Access Format - Watkins-Johnson Company WJ-8718A/MFP Instruction Supplement

Microprocessor front panel option
Hide thumbs Also See for WJ-8718A/MFP:
Table of Contents

Advertisement

TABLES 2-15 through 2-17
Table 2-15. Full Status Command
WJ-8718A/MFP
Byte Number
Binary Code
1
11000100
2
11110xxx
3
xxxxxl10
4
00110100
5
01010110
Controller to Receiver
6
01111000
7
o
0 0 0 1 0 1 0
8
o
1 1 000 0 0
9
OxOOOOOO
J
Table 2-16. Command BFO Frequency
Byte Number
Binary Code
1
11000100
.
2
1 1 1 1 1 0 0 0
3
xxxxx110
~
Controller to Receiver
1
11000100
2
1 1 1 1 1 1 0 1
3
o
1 1 000 0 0
. .
2.4.5.2.9
Access Tier 2 Format
In this example, shown in Table 2-17, it is assumed that the receiver is equipped
with the 1 Hz Tuning Option (in addition to the MFP and 232M Options) and the controller
desires to monitor the status of the 10 0 digit of tuned frequency. The receiver is at address 20
and the 10 0 digit is 6.
Table 2-17. Tier 2 Access Format
Byte Number
Binary Code
1
11010100
J
Controller to Receiver
2
11100111
1 1 101 0 0 0
3
11010100
}
4
1 1 1 000 0 0
Receiver to Controller
5
0110xxxx
2-22