ICDM-RX/TCP Installation and Configuration Guide
ICDM-RX/TCP-16DB9/RJ45-RM, ICDM-RX/TCP-16RJ45/RJ45-RM, and
2.9. ICDM-RX/TCP-16DB9/RJ45-RM, ICDM-RX/TCP-16RJ45/RJ45-RM,
and ICDM-RX/TCP-32RJ45/2RJ45-RM Installation
Use the following procedure to install the ICDM-RX/TCP-16DB9/RJ45-RM (16-port with DB9 ports), ICDM-RX/
TCP-16RJ45/RJ45-RM (16-port with RJ45 ports), or ICDM-RX/TCP-32RJ45/2RJ45-RM (32-port) with an
internal power supply.
1. Place the ICDM-RX/TCP on a stable surface, or optionally mount the ICDM-RX/TCP in a rack.
Rack Installation:
a. Attach the L brackets to the interface using the screws supplied with the unit.
b. You can mount the unit facing in either direction.
c. Attach the L bracket into your rack.
Follow these guidelines when mounting the ICDM-RX/TCP in a rack.
•
If the ICDM-RX/TCP is installed in a closed or multi-rack assembly, the operating temperature
of the rack environment may be greater than the ambient temperature. Be sure to install the
ICDM-RX/TCP in an environment that is compatible with the maximum rated ambient
temperature.
•
Make sure that the mechanical loading is level to avoid a hazardous condition; such as,
loading heavy equipment in the rack unevenly. The rack should safely support the combined
weight of all equipment in the rack.
•
Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of
the ICDM-RX/TCP and to protect it from overheating, maintain a minimum of 1 inch of
clearance on all sides of the unit.
•
AC power inputs are intended to be used with a three-wire grounding type plug, which has a
grounding pin. Equipment grounding ensures safe operation. Do not defeat the grounding
means and verify that the ICDM-RX/TCP is reliably grounded when mounting within the rack.
Note: Do not connect multiple units until you have changed the default IP address, see Initial Configuration on
Page 26.
2. Connect the ICDM-RX/TCP port labeled 10/100 NETWORK to the same Ethernet network segment as the
host PC using a standard network cable.
Do not connect RS-422/485 devices until the IP address is configured and an appropriate
port interface type has been configured (Step 5). The default port setting is RS-232.
3. Apply power to the ICDM-RX/TCP by connecting the appropriate power cord into the power socket on the
ICDM-RX/TCP, plugging the power cord into a power source, and turning on the power switch.
23