ICDM-RX/TCP Installation and Configuration Guide
Changing the Bootloader Timeout
9.6. Changing the Bootloader Timeout
Use the following procedure to change the Bootloader timeout value.
1. Establish communications with the ICDM-RX/TCP using the serial (Page 112) or telnet (Page 113) method.
2. At the RedBoot prompt, type timeout.
RedBoot> dis
Loading disabled
RedBoot> timeout
Timeout 15 seconds
RedBoot> timeout 45
timeout 45 seconds
RedBoot>_
RedBoot responds with the current Bootloader timeout value.
3. Type timeout and a value to change the timeout value. For example, timeout 45 to change the Bootloader
timeout to 45 seconds.
9.7. Determining the Bootloader Version
Use the following procedure to determine what Bootloader version is loaded in the ICDM-RX/TCP.
1. Establish communications with the ICDM-RX/TCP using the serial (Page 112) or telnet (Page 113) method.
2. At the RedBoot prompt, type version.
The Bootloader information displays.
3. Type reset to reset the ICDM-RX/TCP, if you do not have any other related RedBoot tasks.
Note: Optionally, you can install PortVision DX on a Windows system on the network and see the Bootloader
version. Reboot the ICDM-RX/TCP, right-click the ICDM-RX/TCP and click Refresh Device until the
Bootloader version displays. The Bootloader version is only displayed for a few moments.