ODT-MAC335-HD-RD With regard to the supply of products, the current issue of the following document is appli- cable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotech- nik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary...
ODT-MAC335-HD-RD Introduction ..............5 Declaration of conformity........... 6 Safety ................7 Symbols relevant to safety ...............7 Intended use ....................7 Laser class 1....................7 General notes on safety................7 Product description ............ 9 ODT-MAC335 – Use and application ............9 Field of vision and resolution ..............10 Displays and controls ................10...
Page 4
ODT-MAC335-HD-RD Operation via code reading ..............18 7.2.1 Programming different code symbologies..........18 7.2.2 RS 232 operating modes ................30 7.2.3 Continuous reading................... 31 7.2.4 Lighting ..................... 32 7.2.5 Mirror decoding..................32 7.2.6 Prefix and suffix settings ................33 7.2.7 Text command function ................
ODT-MAC335-HD-RD Introduction Introduction Congratulations You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops, produces and distributes electronic sensors and interface modules for the market of automation technology on a worldwide scale. Symbols used The following symbols are used in this manual: Note! This symbol draws your attention to important information.
This product was developed and manufactured under observance of the applicable European standards and guidelines. Note! A Declaration of Conformity can be requested from the manufacturer. The product manufacturer, Pepperl+Fuchs GmbH, D-68307 Mannheim, has a certified quality assurance system that conforms to ISO 9001. ISO9001...
ODT-MAC335-HD-RD Safety Safety Symbols relevant to safety Danger! This symbol indicates a warning about a possible danger. In the event the warning is ignored, the consequences may range from personal injury to death. Warning! This symbol indicates a warning about a possible fault or danger.
Page 8
ODT-MAC335-HD-RD Safety Installation and commissioning of all devices must be performed by a trained professional only. Protection of operating personnel and the system is not ensured if the product is not used in accordance with its intended purpose. Only use recommended original accessories.
ODT-MAC335-HD-RD Product description Product description ODT-MAC335 – Use and application The ODT-MAC335 is a universal reader designed for identifying products and acquiring data online. The range of functions available is far superior to any other individual device. The ODT- MAC335 has a unique lens, a 1.3 million pixel CMOS sensor and a 400 MHz processor. These elements combine to produce a reading system that offers the following features: •...
ODT-MAC335-HD-RD Product description Field of vision and resolution 150 mm 0.51 mm Data Matrix 0.21 mm Data Matrix 100 mm 0.16 mm Data Matrix 50 mm Optimal Focus at 90 mm Wide Optical Field 0 mm 0.08 mm Code 39 50 mm 0.11 mm Code 38...
ODT-MAC335-HD-RD Product description Interfaces and connections The device includes the following connections: Power supply There is an 8-pin M12 plug on the rear of the sensor housing for connecting the power supply and the inputs and outputs. The following diagram shows the pin assignment: Figure 4.3: Connection layout for supply voltage and inputs and outputs...
ODT-MAC335-HD-RD Product description Accessories Various accessories are available. 4.6.1 Power supply Use the following connection cable to connect the power supply, inputs and outputs to the sensor. M12 connection cables Cable end, field attachable Material Length 8-pin M12 socket, V19-G-2M-PUR-ABG...
Check that all items are present and correct based on your order and the shipping documents. If you have any questions, please contact Pepperl+Fuchs. Keep the original packing material in case you need to store or ship the unit at a later time.
ODT-MAC335-HD-RD Installation Connecting the device Make sure that the following conditions are fulfilled: • The housing must be grounded. • Always use shielded cables. Connect the cable shield to the housing on the RS 232 connector. Figure 5.2: Connection layout for supply voltage and inputs and outputs...
ODT-MAC335-HD-RD Installation Connecting RS 232 interface To connect the RS 232 interface, proceed as follows: If necessary, switch off the PC before making connections to the serial interface on the PC. Connect the RX line (pin 3) on the reader to the corresponding TX line on the PC.
ODT-MAC335-HD-RD Commissioning Commissioning Reading a code This reader uses digital camera technology to record an image of the code to be read. After an image has been recorded, the reader uses highly developed evaluation procedures to evaluate the data contained in the recording.
ODT-MAC335-HD-RD Operation Operation Operation using Vision Configurator The “Vision Configurator” software provides you with a user-friendly interface for convenient operation of the reader. With the use of an XML configuration file, the reader can be adapted to the particular requirements of your plant.
ODT-MAC335-HD-RD Operation Operation via code reading You can configure some settings directly by scanning in special codes. The reader uses the following factory settings: • RS 232 mode • 57600 baud • 2 stop bits • No parity • Text commands on •...
Page 19
ODT-MAC335-HD-RD Operation Codablock F Codablock F On Codablock F Off (Default) Save Settings Example: Code 11 Code 11 On (Default) Code 11 Off Code 11 Checksum 1 Code 11 Checksum 1 Code 11 Checksum 2 Save Settings digit digit & Strip from result digit &...
Page 20
ODT-MAC335-HD-RD Operation Code 39 Code 39 On (Default) Code 39 Off Code 39 Enable Code 39 Enable Disable Checksum Checksum Checksum & Strip from (Default) result Code 39 Extended Full Code 39 Extended Full ASCII On ASCII Off (Default) Code 39 Short Margin...
Page 21
ODT-MAC335-HD-RD Operation Code 93 Code 39 On (Default) Code 93 Off Save Settings Example: Code 128 Code 128 On (Default) Code 128 Off Code 128 Short Margin On Code 128 Short Margin Off Save Settings (Default) Example: Composite Composite On...
Page 22
GoCode is a private symbology and can be used by obtaining a fixed-term license. GoCode has many important advantages when compared with usual linear bar codes and 2D symbols. Please contact Pepperl+Fuchs if you require any further information on the advantages of a private symbology.
Page 23
ODT-MAC335-HD-RD Operation Interleaved 2 of 5 Int 2 of 5 On (Default) Int 2 of 5 Off Int 2 of 5 Two Digits On Int 2 of 5 Two Digits Off (Default) Int 2 of 5 Four Digits On Int 2 of 5 Four Digits Off (Default)
Page 24
ODT-MAC335-HD-RD Operation Matrix 2 of 5 Matrix 2 of 5 On (Default) Matrix 2 of 5 Off Save Settings Example: Micro PDF417 Micro PDF417 On Micro PDF417 Off (Default) Save Settings Example: MSI Plessy MSI Plessy On MSI Plessy Off (Default)
Page 25
ODT-MAC335-HD-RD Operation NEC 2 of 5 NEC 2 of 5 On NEC 2 of 5 Off (Default) Save Settings PDF417 PDF417 On (Default) PDF417 Off Macro PDF 417 On Macro PDF 417 Off (Default) Save Settings Example: Pharmacode An explanation of the Pharmacode settings and all programming codes can be obtained from...
Page 26
ODT-MAC335-HD-RD Operation Post Codes All post codes (zipcodes) are deactivated as standard. Scan the following codes to activate the corresponding post symbology. Note! If you wish to change the activated symbologies, first scan the code Disable all Postal Codes and then the post codes for the desired symbology.
Page 27
ODT-MAC335-HD-RD Operation QR Code QR Code On QR Code Off (Default) Enable Checksum Disable Checksum (Default) QR Code Inverse On Both Inverse and Standard On All QR On (includes Micro QR) Inverse QR and Micro QR On Save Settings Example QR Code:...
Page 28
ODT-MAC335-HD-RD Operation RSS Limited On RSS 14 and RSS 14 RSS 14 Stacked On Truncated On RSS Expanded On All RSS On All RSS Off (Default) Save Settings Example RSS Limited Code: Example RSS 14 Code: Example RSS 14 Truncated Code:...
Page 29
ODT-MAC335-HD-RD Operation UPC/EAN/JAN UPC On (Default) UPC Off UPC Short Margin Enabled UPC Short Margin Disabled (Default) UPC Extension On UPC Extension Off Save Settings Example:...
ODT-MAC335-HD-RD Operation 7.2.2 RS 232 operating modes Changing RS 232 communication parameters Scan the respective code to change the individual RS 232 connection settings. RS 232 communication settings Setting data bit 7 data bits 8 data bits (default) Setting stop bit...
ODT-MAC335-HD-RD Operation 7.2.3 Continuous reading In addition to the option of pressing the trigger button to start a reading, you also have the option of using the reader in continuous mode and perform an unlimited number of readings. Several configuration options are available here.
ODT-MAC335-HD-RD Operation 7.2.4 Lighting Activating continuous lighting Deactivating continuous lighting Scan the code Save Settings after selection: 7.2.5 Mirror decoding As soon as mirror decoding is activated, the reader can read codes that are inverted 180°. Furthermore, all other code reading functions are deactivated.
ODT-MAC335-HD-RD Operation 7.2.6 Prefix and suffix settings Caution! Risk of data loss If you scan one of the following codes, data loss may result First save the settings on your handheld before scanning one of the following codes. Defining prefix For presentation of the read data, we recommend - besides the use of suffixes - the use of prefixes as separators between the individual data records.
Page 34
ODT-MAC335-HD-RD Operation Deleting a prefix To delete all prefixes, scan the data matrix code Prefix - Erase: Defining suffix For presentation of the read data, we recommend - besides the use of prefixes - the use of suffixes as separators between the individual data records. You can select between several separators.
ODT-MAC335-HD-RD Operation Deleting a suffix To delete all suffixes, scan the code Suffix - Erase: Deleting prefixes and suffixes To delete all prefixes and suffixes, scan the code Erase Prefix & Suffix Data: 7.2.7 Text command function Activating/Deactivating the text command function To activate or deactivate the text command function, scan one of the following codes.
Information on firmware and the serial numbers of the reader is transferred from the internal reader memory and displayed in the text editing program. Note! Current firmware and upgrades Pepperl+Fuchs regularly releases new firmware for readers. Contact Pepperl+Fuchs for information on current firmware versions or upgrades.
ODT-MAC335-HD-RD Maintenance and repair Maintenance and repair Maintenance The cable and power supply are maintenance-free. To get the best possible performance out of your device, keep the optical unit on the reader clean and always clean whenever necessary. Observe the following instructions when cleaning: •...
ODT-MAC335-HD-RD Troubleshooting Troubleshooting What to do in the event of an error Fundamentally applicable: • Do not use the stationary reader outside of the specified temperature range. • When not in use, always store the stationary reader within the specified temperature range.
ODT-MAC335-HD-RD Appendix Appendix 10.1 Text commands You have the option of sending text commands directly to the reader via the RS 232 interface using serial communication software such as Hyperterminal. Enter the commands directly using the keyboard or send the commands in a file from a library. Press "Enter" (<CR>...
Page 40
ODT-MAC335-HD-RD Appendix Character string Meaning Text command bold print = default setting bold print = default setting Targeting P%04xx<CR>P%c4xx 00;02 = On always on P%0401<CR>P%c4ff 01;ff = Off Motion P%86xx 00 = disable detection P%8600 #03 = enable Sensitivity of...
Page 41
ODT-MAC335-HD-RD Appendix Character string Meaning Text command bold print = default setting bold print = default setting Decode field P%53#xx<CR> Full image: 1280 ; 1024 ; 1024 window P%54#xx<CR> Default: 1280; 640; 640 P(1c7)#xx<CR> P%53#1280<CR> P%C7#640<CR> P%(1c7)#640<CR> Laser target P%0fxx...
Page 42
ODT-MAC335-HD-RD Appendix Character string Meaning Text command bold print = default setting bold print = default setting Interleaved 2 of Q%c9xx 2 = Off 5 four digits Q%c9xx 3 = On Q%c92 O%c92 Checksum P%71xx 0 = disable P%710 1 = enable...
Page 43
ODT-MAC335-HD-RD Appendix Character string Meaning Text command bold print = default setting bold print = default setting UPC short P%74xx 0 = Off margin P%740 1 = On CodaBlock_F P%6dxx<CR>P%cexx<CR 1, 0 = Off symbology > 0, 1 = On P%6d1<CR>P%ce0<CR>...
Page 44
SENSING YOUR NEEDS Pepperl+Fuchs sets the standard in quality and innovative technology for the world of automation. Our expertise, dedica- tion, and heritage of innovation have driven us to develop the largest and most versatile line of industrial sensor technolo- gies and interface components in the world.