Hp 303Lla Tes T Jac K Vol Tages - HP 3000 III Series Manual

Table of Contents

Advertisement

System Installation
n.
Connect the
input lead of the vol tmeter to each of
the test
jacks on
the HP 30311A Power Supply front
panel and compare
the value displayed against table 11-4.
o.
If all the values displayed are out- of tolerance,
proceed no
further until the
+5.00V Internal Reference
Adjustment pro-
cedure described in the HP 3000 Series II/III Computer System
S~rvice
Manual
part
no.
30000-90018 has been
performed on
your HP 3031lA Power Supply.
p.
Repeat steps
m through
0
for each HP 303llA Power
Supply in
the s ys tern.
Table 11-4.
HP 3031lA Test Jack Voltages
-----------1-----------------------
Test Jack
I
Value Required
1
I
-----------1-----------------------
+5B
I
+5.1: +/- 0.1
+l2B
I
+12 • 0: +/ - O. 1
+12.7B
Ivalue of + 12 test jack
I
+0.7(+/- 0.2}
- 3B
1 -
3 • 0: +/ - O. 25
- 5B
1 -
5. 0: +/ - O. 2
I
---~-~~-~~-
--~~~-~~--~-~~-------~-
11-10. SYSTEM VERIFICATION
To
verify that the system operates correctly, turn on all periph-
eral devices and connect them on-line.
Then,
use the QA Verifi-
cation Tape to exercise the system's System Verification Process.
Also run the
appropriate diagnostics in accordance with
the in-
structions contained in the HP 3000 Series II/III Computer System
Service Manual, part no. 30000-90018.
Next, perform the MPE/3000
Cold-Start
Procedure in accordance
with
the
instructions con-
tained in the HP 3000 Computer System Operator's Guide,
part no.
32000- 90 013.
11-14