MCU/Main Memory Overview
I
I
I
I
I
I
01
2 3 4
5 8
71
s
9 10' 11
12
13
14
15
1
:J
\.
J
Y
ZEROS
RROR
SIOOK
R/WOK
INT. PENDING
READ SCAN
DISWEC
L!U512K
=0
READ COPY E
TIO
Figure 6-10.
TIO Word Format
6-45. CIa Command.
CIa instructions may be executed only if
TIO
bit
1
=
1
(R/W OK)
except for a CIa master clear
which can be
executed at any time.
Figure 6-11 shows the word format
of the
CIa instr uction •
Bit 0
Master Clear.
When set,
causes the FLI PCA to
reset
and
inhibits simultaneous Read Copy, Read Scan and/or
DISWEC
CIa
instructions,
or
aborts
any
of
these
oper a tions.
Bit 2
Read Copy.
Causes the contents of the lower or
upper
5l2K
Error Logging Array to be transferred to the I/O
Logging Array
starting at the address location speci-
fied by
bits 6 through 15 and
ending at %1777.
The
Read Copy is completed when the Address Counter
rolls
over to %0000.
During a transfer, TIO bit 1
=
0
(R/W
not
OK)
and goes to a 1 within 50 usec after comple-
tion of a copy.
A Read Copy will be terminated by the
occurrence of a PFW, PON,
I/O
Reset
or
CIa
Master
Clear.
Read Copy
will inhibi t
a simultaneous
Read
Scan and is aborted by a Master Clear.
6-24