Functional Verification
CDMA Mobile Phone Functional Test
• Press the Call/Page key on the Test.
• Test Set should page the mobile.
• Mobile should automatically connect to Test Set.
6. Mobile phone measurements (record all test results in
123.
6a. Receiver FER Test:
• Press the (CDMA SCREENS) RX test key
• Set the Display Interim Results field to Yes
• Set the FER Spec field to 0.50%
• Set Sctr A Pwr: field to –90 dBm/BW (when no isolation box is used)
• Set Meas Cntl filed to Single
• Begin measurement, highlight the Arm field. Test Set should return a
Passed Status
6b. Transmitter Rho Test:
• Press the (CDMA SREENS) TX test key.
• Set Meas Cntl field to Cont. Measured Traffic Rho should be >0.980
6c. Mobile Channel Power Test:
• Press the (CDMA SCREENS) Call control key.
• Set Chan Power field to Chan Power. Measured channel power should be
about ±1.5 dB of the calculated "Ideal Mobile Power" value.
7.
End call - press the End/Release button on the Test Set.
122