Electrical Connections; Drain Line Flow Controller - Pentair AUTOTROL 368 Installer Manual

Table of Contents

Advertisement

Installer manual Autotrol 368 (604-606) - Installation
5.6

Electrical connections

AC transformer cable connection
Motor and optical sensor cable connection
Meter cable connection (368/606 only)
5.7

Drain line flow controller

The DLFC requires assembly before use.
Info
The plumbing connectors should not be installed. See Bypass assembly [
1. Using a PTFE (plumber's tape), wrap it over threads of the flow controller (2).
2. Screw the flow controller (2) and the 90° elbow (1) together (hand tighten).
3. Place the ball (5) into the flow controller (2) and insert the assembly into the drain line
opening (4).
4. Push the assembly in and secure with the drain line clip (3).
26 / 60
AC transformer connection
Page 27]
Ref. MKT-IM-007 / D - 09.10.2020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

604605606

Table of Contents