Check I/O Error - Skyjack SJ85 AJ Service Manual

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Platform

5.1-6 Check I/O Error

If a fault is detected, the engine shuts off and the SCM displays "Check I/O Err? Press select".
This check helps to determine which channel has the fault.
Use the chart below to determine which function each channel is related to. A properly working channel is
indicated by a "0". A fault is indicated by a "1".
Check IO Err?
PRESS SELECT
PE 1 2 3 4 5
0 0 0 0 0
PE 6 7 8 9 10
0 0 0 0 0
PE 11 12 13 14 15
0 0 0 0 0
Example:
PE 6 7 8 9 10
0 1 0 0 0
This example indicates an
error (1) in channel 7,
which is the Riser Down
function.
SJ85 AJ
MENU
SELECT
+
SAVE
EXIT
Section 5 – Procedures
Channel Functions
DRIVE REV
1
DRIVE FWD
2
ROTATE L
3
ROTATE R
4
BOOM DOWN
5
BOOM UP
6
RISER DN
7
RISER UP
8
FLY OUT
9
FLY IN
10
JIB DOWN
11
JIB UP
12
PLATF RGT
13
PLATF LFT
14
PROP FLOW
15
229044ADA
149