Section 4 – Troubleshooting Information
No Boom Extend from Base or Platform Consoles:
1. Loose or broken wire #39 from base terminal
block to load sense/dual load zone module white
connector J4 pin 6.
2. No output on load sense/dual load zone module
white connector J4 pin 3 to wirer 39A.
3. Loose or broke wire #39A from load sense/dual
load zone module white connector J4 pin 3 to
harness plug pin #13.
4. Loose or broke wire #39A from harness plug pin
#13 to boom extend valve 4H-39A.
5. Loose or broken wire #02 from turret harness
plug to boom extend valve 4H-39A.
6. Defective boom extend coil 4H-39A.
229044ADA
114
Check continuity. Replace if defective.
Check pin #5 for 12 volts. If no voltage present
when operating down function check section 5 for
module information.
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check continuity and resistance through coil.
Replace if defective.
Electrical System