5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
791
411
0
793
411
0
795
411
3
796
411
4
805
524025
14
806
524058
2
807
3253
2
809
3251
0
810
3251
0
812
3251
1
813
3251
1
814
3253
3
815
3253
4
825
523009
9
826
523470
2
827
523470
2
828
523470
12
829
523470
12
830
523470
14
831
523470
11
832
523470
11
833
523009
10
834
523906
5
835
523906
12
836
523906
3
837
523906
4
847
1176
0
848
1176
1
849
1176
3
850
1176
4
856
523613
0
229044ADA
180
6-9-3
Delta pressure across venturi in EGR line above physical high limit.
Plausibility Check fault for deviation of desired and actual EGR-mass flow,
6-9-3
where the latter is calculated out of EGR Delta Pressure Sensor.
6-9-3
Sensor error differential pressure Venturiunit (EGR), signal range check low.
6-9-3
Sensor error differential pressure Venturiunit (EGR), signal range check high.
Particulate filter regeneration.
(3x) over the max. has been aborted allowed recovery time.
8-4-5
Regeneration after time X is not successful (the error occurs when the
regeneration times).
8-4-4
Particulate filter; regeneration not succesful.
6-9-2
Differential pressure DPF, plausibility error.
6-9-2
Differential pressure DPF maximum value is exceeded.
6-9-2
Differential pressure sensor across DPF exceeds warning high limit.
6-9-2
Differential pressure DPF, pressure below lower shutoff threshold.
6-9-2
Differential pressure DPF, pressure below lower warning threshold.
6-9-2
Electrical error differential pressure B58 (DPF). (Signal range check high).
6-9-2
Electrical error differential pressure (DPF). signal range check low.
The pressure relief valve (PRV) has reached the number of allowed
2-5-3
activations.
1-4-6
Pressure relief valve is forced to open, perform pressure increase.
1-4-6
Pressure Relief Valve (PRV) forced to open. Performed by pressure increase.
1-4-6
Pressure Relief Valve (PRV) forced to open. Shutoff conditions.
1-4-6
Pressure Relief Valve (PRV) forced to open. Warning conditions.
1-4-6
Open Pressure Relief Valve (PRV).
1-4-6
Pressure Relief Valve (PRV) error; Rail pressure out of tolerance range.
Rail pressure out of tolerance range.
1-4-6
The PRV can not be opened at this operating point with a pressure shock.
Open time of Pressure Relief Valve (PRV) for wear out monitoring had
2-5-3
exceeded.
7-6-1
Electrical fuel pre - supply pump; open load.
7-6-1
Electrical fuel pre - supply pump. ECU powerstage over temperature.
7-6-1
Electrical fuel pre - supply pump; short circuit to battery.
7-6-1
Electrical fuel pre - supply pump. Short circuit to ground.
1-3-9
Pressure sensor upstream turbine, Physical Range Check high.
1-3-9
Pressure sensor upstream turbine, Physical Range Check low.
1-4-1
Pressure sensor upstream turbine, signal range check (SRC) high.
1-4-1
Pressure sensor upstream turbine, signal range check (SRC) low.
1-3-4
Rail pressure metering unit, Positive governor deviation.
Error Identification
Deutz Diesel Engines