Skyjack SJ85 AJ Service Manual page 179

Articulating boom
Hide thumbs Also See for SJ85 AJ:
Table of Contents

Advertisement

Deutz Diesel Engines
5.6-6 Deutz TD2.9L Fault Codes
Code SPN FMI Blink Code
970
624
12
971
624
3
972
624
4
973
523612
14
974
523612
14
975
523612
14
976
91
11
978
29
2
980
523550
12
981
172
3
982
172
4
986
523921
0
989
523921
1
992
105
1
994
105
3
995
105
4
996
105
0
997
105
0
998
105
11
1007
412
3
1008
412
4
1011
523960
0
1012
523960
1
1014
51
6
1015
520521
5
1016
51
7
1022
51
6
SJ85 AJ
5-1-3
SVS lamp: powerstage over temperature
5-1-3
SVS lamp; short circuit to battery
5-1-3
SVS lamp; short circuit to ground
5-5-5
Softwarereset CPU SWReset_0
5-5-5
Softwarereset CPU SWReset_1
5-5-5
Softwarereset CPU SWReset_2
2-2-6
Plausibility error between APP1 and APP2 or APP1 and idle switch.
Plausibility error between sensor and idle switch, Acceleratio Pedal
Detection.
1-2-6
In case of Hand Throttle with Low Idle Switch, it is the plausibility check
between hand throttle and idle switch.
5-1-5
Terminal 50 was operated too long.
2-2-6
Air flow temperature sensor; short circuit to battery or open load.
2-2-6
Air flow temperature sensor; short circuit to ground.
7-1-4
Burner temperature, temperature above upper shutoff threshold.
7-1-4
Burner temperature, temperature below lower shutoff threshold.
Charged Air cooler down stream temperature. Temperature below lower
1-2-8
physical threshold.
1-2-8
Electrical error charged air temperature. Signal range check high.(SRC)
1-2-8
Electrical error charged air temperature. Signal range check low.
Charged air cooler temperature. System reaction initiated. High charged air
2-3-3
cooler temperature. Warning threshold exceeded.
2-3-3
High charged air cooler temperature. Shut off threshold exceeded.
Diagnostic fault check for charged air cooler downstream temperature
1-2-8
sensor
No detailed information!
Electrical error EGR cooler downstream temperature. Signal range check
6-8-2
high.
6-8-2
electrical error EGR cooler downstream temperature. Signal range check low.
7-7-1
Physical range check high for EGR cooler downstream temperature.
7-7-1
Physical range check low for EGR cooler downstream temperature.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8).
5-9-4
Signal range check high.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); signal range
5-9-4
check low.
Actuator position for EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8) not
5-9-4
plausible.
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (4.1;6.1;7.8); signal range
5-9-4
check high
Error Identification
Section 5 – Procedures
1513AA-13
229044ADA
183

Advertisement

Table of Contents
loading

Table of Contents