Section 5 – Procedures
Standstill Regeneration Stages
Standstill
Lamps
3
4
Flashes slowly
Flashes slowly
Flashes quickly
Perform the Standstill Regeneration
1. Move the MEWP to an open, well-ventilated area,
away from any flammable material. Park it on a
firm level surface, and fully stow the MEWP .
2. With the engine running, turn the off/base/
platform switch
7
base position.
3. Activate the standstill regeneration by moving
the standstill switch
the right. Base functions become inoperative
when the standstill switch is turned on.
4. On the engine display module
the middle button
symbol) for 7 seconds.
WARNING
Do not touch hot engine components. Touching
hot surfaces may cause serious injury.
5. The engine display module changes to the
Regeneration Ongoing symbol
lamps turn solid, and the engine speed may
change.
6. Standstill regeneration takes approximately
45 minutes. During this time, the MEWP must
not be used.
229044ADA
192
Engine
Audible
Lamp
Alarm
5
Pulsates
Off
slowly
Pulsates
On
slowly
Pulsates
Flashes
quickly
on the base controls to the
on the base controls to
8
press and hold
2
(below the regeneration
9
, the standstill
10
Engine
Torque
6
Perform the standstill operation at the next available
100%
opportunity, within 3 to 4 hours.
The standstill operation must be performed
75%
immediately.
a. The standstill operation is no longer possible with
on-machine controls.
Contact an authorized repair facility.
40%
b. Failure to perform the standstill has resulted in
the diesel particulate filter failure, and regeneration
is no longer possible. Contact an authorized repair
facility to replace the filter.
IMPORTANT
The standstill regeneration must be completed
fully. If the process is interrupted, the standstill
request continues.
7. When the standstill regeneration is complete,
the Regeneration Ongoing symbol changes to
Regeneration Complete
turn off, and the engine speed returns to
3
4
normal.
8. Move the standstill switch to the left. The MEWP
may now be used normally.
IMPORTANT
The derate override switch
platform control box should only be used when
absolutely necessary to move the MEWP to park it
in a safe location when the derated engine torque/
rpm prevents adequate torque to drive the MEWP .
It will temporarily (for approximately 30 minutes)
restore full engine power and speed.
Be aware that use of the derate override switch
may result in diesel particulate filter failure.